Power Connector:
The electrical professional must be qualified to connect the power for the fixture.
Confirm the power voltage requirement with the power marked on the lamp. Ensure
it has
overload and leakage protection
Caution:
Connect the equipment to the power supply directly. Do not connect to the
silicon box color system, otherwise it may damage the device.
The power line must
have a stand
ard 3
-
pin plug and socket, in which the yello
w/green line can be
connected to the ground. If in doubt, consult a qualified electrician
Power supply color
Brown
Blue
Yellow and green
plug
Fire wire
The zero line
Ground line
mark
L
N
LIGHT BULB INSTRUCTI
ONS
Philips 189W bulb Osram
230W bulb Philips 260W bulb
Caution:
Installing any other types of bulbs may cause potential safety hazard and
equipment damage. In order to reduce the risk of lamp damage, change the bulb
before the light bulb exceeds 125% of its lifespan.
Caution:
When changing the bulb, handle it with care. Do not touch the surface
of the bulb to avoid oil contamination. Bulbs must be kept clean. To clean the bulb,
use the paper provided. Bulb leading wires must be inserted securely. Contact of
terminal can damage bulbs. Ensure bulbs are in place and cooling fan wires are
correctly positioned. Routing wires shouldn’t block the fan blade or window
otherwise it will affect the bulb’s cooling effect.
1. Disconnect the power supply and let the lamps cool down. Position the lamp
head horizontally with the Y-axle locked.
2. Screw off the four cross screws of the 4*12 type on the top.
3. Screw off the three wires of the speed fan of 80*80 type.
Содержание RAY 7R