16
Ray 7R Moving Beam – User manual
Routine Maintence
Routine maintenance is vital for the operation of the equipment
. The life span can be
maintained and extended if regularly maintenance checks take place.
Caution:
Switch off
the power supply before opening/disassembling the fixture.
1. Clean the optical parts
The optical parts should be wiped gently as there is a
coating on the surface which can
be scraped easily. Solvent must not be applied as if can cause damage to the plastic
and coating surfaces.
Cleaning steps:
Turn off the power supply and allow to cool.
Blow away any dust and floats with vacuum or blower.
Wipe off the graininess with odorless tissue or cotton saturated with rinsing or
distilled water. Do not wipe surface.
Wipe off the dust with cotton soaked in propanol, odorless tissue or glass cleaner.
Residue dust must be wiped off with distilled water
then scrubbed clean with soft
cotton.
2.
Clean the fan and air hole
Overheating the equipment is caused by a blockage in the fan air hole, and can lead to
operation failure.
Wipe off dust stuck in the fan and air hole with a soft brush, cotton, vacuum
or
blower.
3. Cleaning regularly
Wipe off the dust from the light body, lens, reflector, inside and PCB regularly.
Tighten pendent parts, swing and twirling nuts regularly
Add lubricant to the rolling part regularly
Check the working motor wires and conn
ecting wires regularly.
4. Gobo plate swabbing
In order to keep the gobo plate swirling continually and freely, swabbing should be
done every six months with lubricant. Do not overuse the lubricant to avoid splashing
and spillage.
5. In order to keep t
he light in the best working state, clean and dust it regularly. Wipe
off the dust on gobo and optical filter with soft cotton soaked with glass cleaner. Do
NOT use solvent or alcohol.
6. Deliver the light to professionals to apply a routine maintenance a
fter one year of
use.