background image

 

   

   

   

19   

Ray 7R Moving Beam – User manual 

6

TECHNICAL 

S

PECIFICATION

S

 

 

o

 

Bulbs

Philips 189W bulb   Osram 230W bulb   Philips 260W bulb

 

o

 

Channel 

17 international standard DMX signal channels 

 

o

 

Horizontal scan

540°(16bit precise scan)  Automatically correct 

 

o

 

Tilt scan

270° (16bit precise scan)  Automatically correct

 

o

 

HD LCD ,four Touch 

switches ,reversible 180°display and operate

 

o

 

Color Wheel :one color wheel, consist of 14 color sheets plus white

 

o

 

Gobo Wheel :17 Gobo effects 

 

o

 

Effects wheel

One rotatable 8 lens

Effects movement ,Frost function

 

o

 

0

100%Mechanical dimmer, supports mechanical 

strobe

support strobe macro 

function

 

o

 

Lens unit optical system , Electric focus

Beam angle 0

 

o

 

Overheating protection measures to turn off the bulb

 

o

 

Bulb cooling fan damage and irregular rotation speed protection measures to turn 

off the bulb

 

o

 

Power 

100

-

24

0V

50/60Hz

 

o

 

Rate of work

230W

 

o

 

IP protection grade :IP20

 

o

 

Electric ballast AC/DC power supply 

 

o

 

Flight case size : 75CM 

length

×

46CM 

width

×

69CM

height

 

o

 

2Sets within one case ,face up .

 

o

 

Net weight 

19.5KG

 

Содержание RAY 7R

Страница 1: ...RAY 7R MOVING BEAM USER MANUAL ...

Страница 2: ...tionS 4 3 Product diagram 5 4 Features 5 Installation 6 Safety 6 Equipment mounting bracket installation 6 Device Power 7 Light Bulb Instructions 8 Operating and control methods 9 Control Panel Instructions 9 Control panel menu functions 10 The Control Panel 12 Function Table of DMX Control Channel 14 5 Trouble Shooting 17 6 Technical Specifications 19 ...

Страница 3: ...technology which is smart efficient and smooth to operate It has internationally advanced electronic control technology and an intuitive industrial design CONTENT LIST o Ray 7R Moving Beam x1 o User Manual x1 o Drawbridge x1 o Signal Line x1 o Power cord x1 o Bulb x1 2 SAFETY INFORMATION SAFETY NOTES Seek advice from a professional prior to authoring any repairs Always ensure the system is disconn...

Страница 4: ...ncy and voltage of the power source corresponds with projector according to the electrical data label o The maximum temperature that can be reached on the external surface of the fitting in a thermally steady state is 100 C o Before starting any maintenance work or cleaning the projector disconnect from the main power supply o After switching off do not remove any parts of the fitting for at least...

Страница 5: ...orizontal scanner 540 and aVertical scanner 270 each with a 16 bit scanning accuracy It is both smooth and precise and the scanning speed is adjustable o Color wheel 14 color film white light o Gobo wheel 17 fixed gobos white circle o Prism wheel includes an eight prism and can rotate in both a positive and negative direction with 16 macro functions o Dimming 0 100 Linear dimming ...

Страница 6: ... for the installation of this fixture o Ensure all parts of the fixture are in good condition before installing o Ensure the point of anchorage is stable before positioning the projector o The safety chain must be properly hooked onto the fitting and secured to the framework so that if the primary support system fails the fitting falls as little as possible EQUIPMENT MOUNTING BRACKET INSTALLATION ...

Страница 7: ...e drawbridge to the light base by screwing the fastener clockwise 4 If the truss can go up and down the device can be directly clamped from the flight box When the equipment is lifted up place the obstacles underneath the work area 5 Secure the fixture with a safety rope and ensure that it can withstand 10 time the weight of the lamp 6 Verify that is nothing combustible within 1 meter of the fixtu...

Страница 8: ...ulb Philips 260W bulb Caution Installing any other types of bulbs may cause potential safety hazard and equipment damage In order to reduce the risk of lamp damage change the bulb before the light bulb exceeds 125 of its lifespan Caution When changing the bulb handle it with care Do not touch the surface of the bulb to avoid oil contamination Bulbs must be kept clean To clean the bulb use the pape...

Страница 9: ...y UP Increase the value shown or continue to the previous item When setting parameters keep holding the UP key to increase the parameter rapidly ENTER Enter into the setting menu whilst on standby enter into the next menu or confirm and save the parameter If you don t press the key all the settings will not be saved Pressing the DOWN and UP keys simultaneously while the display is in the rest mode...

Страница 10: ... Power on time Clear time Lamp on time Clear time Lamp strike Reset strikes 5 Fan monitor 6 Info Feedback 3 Options 1 Pan Inverse 2 Tilt Inverse 3 Pan Tilt Swap 6 Reset via DMX 4 Lamp on via DMX 8 Lamp off if no DMX 7 Lamp on by powon 5 Lamp off via DMX 4 Setting 1 language 2 Display 3Factory set Simplified Chinese English Brightness Light Mode Light Time Display Inverse CONTROL PANEL MENU FUNCTIO...

Страница 11: ... Moving Beam User manual 5 Manual control 1 Lamp on or off 2 Reset Function 3 Adj DMX values Reset all Reset Effect Reset Pan Tilt Lamp on Lamp off 6 Test 1 DMXvalues 2 Run program 7 Advanced Access code _ _ _ _ ...

Страница 12: ...sion Disp Board 1 50 Pan Tilt 1 50 8ch Board 1 50 Display version information Fan Monitor Fan Speed RPM Lamp fan 1 Lamp fan 2 Display the speed of bulb fan Turn off the bulb when speed is abnormal to avoid breaking the bulb because of poor cooling reference value Fan 1 4500 5500r Fan 2 3200 4000r Options Pan Inverse ON OFF According to the scene choose the horizontal scan direction Tilt Inverse ON...

Страница 13: ...ht time Screen lighting time automatically 20s Changeable values 5 60s Inversion Display inversion ON OFF Factory reset Cancel Confirm Factory reset Manual control Lamp on or off Lamp on or off Turn on or turn off Reset function Reset all Reset the entire light Reset Effect After resetting all select particular reset eg color gobo strobe lens reset Reset Pan Tilt After resetting all select horizon...

Страница 14: ...ow Turn on Symmetrystrobeslow fast Turn on Single step Single step Single step Single step Single step Single step Single step Linear Single step Linear Single step Linear Single step CH4 Fixed Gobo DMX Value Effect Attribute 250 255 249 244 237 243 231 236 224 230 218 223 212 217 205 211 199 204 192 198 186 191 180 185 173 179 167 172 160 166 118 159 114 117 72 113 68 71 64 67 60 63 56 59 52 55 4...

Страница 15: ...st angle 0 008 CH11 X axle fine adjustment DMXValue Effect Attribute 0 255 XaxleMicrorotation 0 2 12 Linearity Explanation CH11 Each unit adjust angle 0 98 CH12 Y axle Movement DMXValue Effect Attribute 0 255 Yaxlerotation 0 540 Linearity Explanation CH13 Each unit adjust angle 0 004 CH13 Y axle fine adjustment DMX value Effect Attribute 0 255 Y axle fine tuning 0 0 98 Linearity CH 14 macro functi...

Страница 16: ...ed off with distilled water then scrubbed clean with soft cotton 2 Clean the fan and air hole Overheating the equipment is caused by a blockage in the fan air hole and can lead to operation failure Wipe off dust stuck in the fan and air hole with a soft brush cotton vacuum or blower 3 Cleaning regularly Wipe off the dust from the light body lens reflector inside and PCB regularly Tighten pendent p...

Страница 17: ...poor connection between the bulb and trigger wire E Check whether the fan speed is abnormal or damaged on the panel menu F The ballast has been damaged G Service voltage is insufficient The bulb has become dim A The bulb may have expired If so change the bulb B Check if the optical parts are clean C Conduct a routine maintenance check to the bulb and other inner parts The motor is not working A Ch...

Страница 18: ...ontroller has been damaged or the signal is incompatible The shadow casted has a halo A Check whether the channel value of focusing is suitable for the projection distance The lights work intermittently A Check whether the fan is working and ensure it is free from dust The lights can t be instructed by the controller although it is light A Check the digit start site and connection condition of the...

Страница 19: ...ts plus white o Gobo Wheel 17 Gobo effects o Effects wheel One rotatable 8 lens Effects movement Frost function o 0 100 Mechanical dimmer supports mechanical strobe support strobe macro function o Lens unit optical system Electric focus Beam angle 0 4 o Overheating protection measures to turn off the bulb o Bulb cooling fan damage and irregular rotation speed protection measures to turn off the bu...

Отзывы: