TECHNICAL CHARACTERISTICS
NATURAL GAS MODEL
Solo
AquaSpeed
Excellence
Central heating
24
32
24
32
24
32
Max. Input 80/60°C
kW
24
32
24
32
24
32
Min. Input 80/60°C
kW
5,9
5,9
5,9
5,9
5,9
5,9
Max. output 80/60°C
kW
23,4
31
23,4
31
23,4
31
Min. output 80/60°C
kW
5,8
5,8
5,8
5,8
5,8
5,8
Effi ciency 30% load [EN677]
%
109
109
109
109
109
109
Flue gases
CO emissions max. / min. Input
mg/kWh
45 / 20
52 / 20
45 / 20
52 / 20
45 / 20
52 / 20
NOx emissions [EN483]
mg/kWh
66
66
66
66
66
66
NOx classifi cation [EN483]
5
5
5
5
5
5
Flue gas temperature — max. Input 80/60°C
°C
70
76
70
76
70
76
Flue gas temperature — max. Input 50/30°C
°C
37
39
37
39
37
39
Mass fl ow rate of combustion products
kg/h
38
52
38
52
38
52
Flue gas pipe - Max. pressure drop
Pa
130
130
130
130
130
130
Concentric fl ue gas channel maximum length Ø 80 / 125 mm
m
20
20
20
20
20
20
Gas
Category [varies by country]
I 2E[S]B — I 2Er — I 2H — I 2ELL — I 2L — I 2E
Gas pressure
mbar
20/25
20/25
20/25
20/25
20/25
20/25
G20 gas fl ow rate
m
3
/h
2,5
3,4
2,5
3,4
2,5
3,4
G25 gas fl ow rate
m
3
/h
3,0
3,9
3,0
3,9
3,0
3,9
CO
2
max. Input G20/25
(with front panel closed)
% CO
2
9,3
9,3
9,3
9,3
9,3
9,3
CO
2
max. Input G20/25
(with front panel open)
% CO
2
9,0
9,0
9,0
9,0
9,0
9,0
CO
2
min. Input G20/25
(with front panel closed)
% CO
2
9,2
9,2
9,2
9,2
9,2
9,2
Hydraulic parameters
Max. operating temperature
°C
90
90
90
90
90
90
Boiler water capacity
L
8
8
14
14
16
16
Domestic hot water circuit capacity
L
-
-
0,9
0,9
54
54
Maximum operating pressure central heating
bar
3
3
3
3
3
3
Heat exchanger pressure drop [
Δ
T = 20°C]
mbar
131
210
131
210
131
210
Capacity of the expansion vessel
(depend of countries)
L
-
-
-
-
12
12
Electrical connection
Class
IP
30
30
30
30
30
30
Supply voltage
V/Hz
230 / 50
230 / 50
230 / 50
230 / 50
230 / 50
230 / 50
Maximum absorbed electrical power
A
0,8
0,8
1,2
1,2
1,2
1,2
Weight empty
kg
48
48
63
63
92
92
Содержание AquaSpeed 24