![Prestige AquaSpeed 24 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/prestige/aquaspeed-24/aquaspeed-24_installation-operating-and-servicing-instructions_1598118008.webp)
EN • 8
ENGLISH
FRANCAIS
NEDERLANDS
ESP
AÑOL
IT
ALIANO
DEUTSCH
TECHNICAL CHARACTERISTICS
PROPANE MODEL
Solo P
AquaSpeed P
Excellence P
Central heating
24
32
24
32
24
32
Max. Input 80/60°C
kW
24
30,5
24
30,5
24
30,5
Min. Input 80/60°C
kW
5,9
5,9
5,9
5,9
5,9
5,9
Max. output 80/60°C
kW
23,4
29,6
23,4
29,6
23,4
29,6
Min. output 80/60°C
kW
5,8
5,8
5,8
5,8
5,8
5,8
Effi ciency 30% load [EN677]
%
109
109
109
109
109
109
Flue gases
Flue gas pipe - Max. pressure drop
Pa
130
130
130
130
130
130
Concentric fl ue gas channel maximum length Ø 80 / 125 mm
m
20
20
20
20
20
20
Gas
Category [varies by country]
I 3P
Gas pressure
mbar
30 / 37 / 50
G31 gas fl ow rate
m
3
/h
0,98
1,3
0,98
1,3
0,98
1,3
CO
2
max. Input G31
(with front panel closed)
% CO
2
11
11
11
11
11
11
CO
2
max. Input G31
(with front panel open)
% CO
2
10,7
10,7
10,7
10,7
10,7
10,7
CO
2
max. Input G31
(with front panel closed)
% CO
2
10,9
10,9
10,9
10,9
10,9
10,9
Hydraulic parameters
Max. operating temperature
°C
90
90
90
90
90
90
Boiler water capacity
L
8
8
14
14
16
16
Domestic hot water circuit capacity
L
-
-
0,9
0,9
54
54
Maximum operating pressure central heating
bar
3
3
3
3
3
3
Heat exchanger pressure drop [
Δ
T = 20°C]
mbar
131
210
131
210
131
210
Capacity of the expansion vessel
(depend of countries)
L
-
-
-
-
12
12
Electrical connection
Class
IP
30
30
30
30
30
30
Supply voltage
V/Hz
230 / 50
230 / 50
230 / 50
230 / 50
230 / 50
230 / 50
Maximum absorbed electrical power
A
0,8
0,8
1,2
1,2
1,2
1,2
Weight empty
kg
48
48
63
63
92
92
Содержание AquaSpeed 24