INSTALLATION
INSTALLATION OF TWO HEATING CIRCUIT
CONTROLLED BY CONTROL UNIT AND
ZMC-1 MODULE
General diagram
This configuration controls two heating circuits (radiators
or floor heating). In addition, the Room unit features a
remote monitoring of the two circuits
You can adjust those two circuits depending on the outside
temperature.
This is the ideal configuration for floor heating with additional
heating provided by radiators.
You can select various heating functions, and program up
to three weekly schedules, as well for the central heating as
for the hot water production.
AF120
Room Unit
MCBA
RAM
VF202
ZMC1
Optional accessories
Code
Description
10800034
Room Unit RSC
Supplied with outside temperature sensor
10800119
ZMC-1 module (kit) :
Controls the second heating circuit - alarm contact - operates only in conjonction with
the Room Unit RSC.
10800036
Clip-in interface RMCIEBV3
Enables communications between the MCBA and the Room Unit RSC.
10800045
Contact sensor 2k
Ω
— VF202 :
To be mounted on the outlet of controlled circuit
10510900
Contact thermostat RAM 5109 :
Required to protect all fl oor heating circuits
10510100
Outside temperature sensor 12k
Ω
— AF120
10800077
Collector 2 circuits DN20 :
With bypass, connecting tubes and integrated wall brackets
10800097
High temperature kit DN20
Including: one circulation pump, two isolating valves, check valve, two thermometers
10800096
Low temperature kit DN20
Including: one circulation pump, two isolating valves, check valve, two thermometers,
the 4-way valve with integrated bypass.
10800019
Servomotor SQK 349 :
Electromechanical servomotor SQK 349 for the three-way valve included in low
temperature kit
(opening times : 150 seconds)