6. Inspection, maintenance and desludging
Premier Tech
27 / 64
Solido SMART
DOKK5110E 15.04.2020
6.4
Take sample of activated sludge from reactor chamber
•
measure
current water level
in reactor (
HR
)
•
aerate reactor per manual mode for 2min
•
evaluate mixing and size of bubbles
•
take
250 ml sample of mixed activated slugde
and fill into 1000 ml cylinder
•
fill up with
750 ml of clearwater
from sample pot (using the small sample
taking device) to reach “1+3 dilution”
•
allow
settlement for 30min
•
multiply resulting sludge level by factor 4
to get
SSV30 in ml/l
•
take
picture
and save it as part of maintenance report
•
Measure sludge volume in all chambers/tanks.
•
Contrary to regular SBR-plants the Solido SMART system is working with
comparatively high sludge volume values.
Why dilute 1+3?
Example after 30min
sedimentation:
The result of
600ml/l
is
much closer to the real
conditions in the tank.
Undiluted
SSV30=
930ml/l
Dilution „1+3“:
SSV30= 150ml/l x 4 =
600 ml/l