background image

PP-FCTA-QL

Contact Premier Mounts with any questions: 
(800) 368-9700

Contents

Warning Statements

Weight Limit

Maximum Projector Weight: 

50 lbs.

THE CEILING STRUCTURE MUST BE CAPABLE OF 
SUPPORTING AT LEAST FOUR TIMES THE WEIGHT OF 
THE PROJECTOR. IF NOT, THE CEILING STRUCTURE 
MUST BE REINFORCED. 

 PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND 

COMPLETELY UNDERSTOOD. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION 

FOR FUTURE REFERENCE.

 PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE FOLLOWED, AS OUTLINED 

IN THESE INSTALLATION INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE, SERIOUS 

PERSONAL INJURY, OR EVEN DEATH.

 SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE 

PROPER SAFETY EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.

 PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS 

PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY 

UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, 

DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR 

IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.

 

 At least two qualified people should perform the assembly procedure. Personal injury and/or property damage can result 

from dropping or mishandling the projector.

 

 This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious 

personal injury.

 

 Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of 

impact.

Weight Limit. .................................................................................................................................................................... 2

Warning Statements. ....................................................................................................................................................... 2

Installation Tools. ............................................................................................................................................................. 3

Parts List.......................................................................................................................................................................... 3

Features. ......................................................................................................................................................................... 4

PP-FCTA-QL Installation. ................................................................................................................................................ 5

Cutting the Access Hole. ................................................................................................................................................. 5

Mounting the PP-FCTA-QL. ............................................................................................................................................. 6

Securing the Ceiling Plate. .............................................................................................................................................. 7

Electrical Box Cut-out Removal. ...................................................................................................................................... 7

Ceiling Attachment........................................................................................................................................................... 8

Quick Lock Installation................................................................................................................................................... 10

Securing 1 ½˝ NPT to the PP-FCTA-QL. ....................................................................................................................... 13

Securing the Camera (optional)..................................................................................................................................... 13

Technical Specifications. ............................................................................................................................................... 14

Warranty. ....................................................................................................................................................................... 15

Disclaimer. ..................................................................................................................................................................... 15

Page 2

Содержание PP-FCTA-QL

Страница 1: ...0 International 1 714 632 7100 1321 S State College Blvd Fullerton CA 92831 USA Installation Guide Installationsanleitung Gu a de Instalac on Guida de Installazione Guide d Installation Installatie gi...

Страница 2: ...MOUNTS PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS AND IS NOT RESPONSIBLE FOR ANY DAMAGES CLAIMS DEMANDS SUITS ACTIONS...

Страница 3: ...of these parts are missing and or damaged before beginning the installation If there are parts missing and or damaged please stop the installation and contact Premier Mounts at 800 368 9700 Main Ceili...

Страница 4: ...familiarize yourself with the contents of the package and make sure you have all the parts and tools you need to safely complete the installation In addition some steps of this installation may requi...

Страница 5: ...he ceiling tile C 8 Insert the escutcheon ring into the hole and gently push it into place D A B Ceiling Tile Drill Hole Cutter Mounting Hole Escutcheon Ring C D Hand Escutcheon Ring The escutcheon ri...

Страница 6: ...de of the tile do this for all four edges of the ceiling tile 4 The mounting hole should be located in the center most location of the ceiling tile 5 Once the mounting hole has been cut place the ceil...

Страница 7: ...lectrical installation environment install the electrical box and secure it to the ceiling plate assembly 3 Make all electrical connections at this time Electrical Box Cut out Securing the Ceiling Pla...

Страница 8: ...cks and 1 16 braided cables supplied Anchoring eye bolts are commercially available 1 Determine the mounting location 2 Use a concrete drill bit to pre drill the mounting holes 3 Place the concrete an...

Страница 9: ...pen end of the 1 16 braided cable through the hole in the loop 3 Pull the open end down until the 1 16 braided cable tightens around the truss 4 Repeat through for the remaining three mounting points...

Страница 10: ...tional input arrows To release the 1 16 braided cable slide the release pin to disengage Please follow the steps below in numerical order and to correctly install the Quick Lock Cable Kit Cable Output...

Страница 11: ...PP FCTA QL 1 16 Braided Cable Mounting Hole Release Pin 1 16 Braided Cable Mounting Hole Release Pin Page 11...

Страница 12: ...3 Once attained pull the 1 16 braided cable through the other side of the Quick Lock 4 Once the tension has been adjusted be sure that there is a minimum of 6 of excess 1 16 braided cable on the non w...

Страница 13: ...ch screw hole on the upper adapter plate you will use to attach the camera 2 Insert one 1 1 4 20 x 2 3 4 pan Phillips head screw commercially available through one 1 wing nut commercially available an...

Страница 14: ...TA QL Technical Specifications All measurements are in inches 3 25 8 43 6 50 75 1 00 81 24 75 1 18 4 50 114 3 3 50 88 90 24 45 621 PIPE THREADS 1 5 NTP SLIDING PLATE 1 18 30 1 23 25 590 5 23 70 602 Pa...

Страница 15: ...MITATION OR EXCLUSION MAY NOT APPLY TO YOU What Customers Must Do for Limited Warranty Service If you discover a problem that you think may be covered by the warranty you MUST REPORT it in writing to...