![Pregis 1153-02 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/pregis/1153-02/1153-02_operators-manual_1595293030.webp)
SX™ Operator Manual
©
Original Printed in English
SERVICE SCREENS
Service Screen 2
Raise Print Head
– The Printer Option must be enabled in the Admin Screen before this service button is
active. Pressing it will deenergize the elctrical solenoid and raise the print head. The Print Head Lowered
sensor will switch off when the head raises.
Lower Print Head
– The Printer Option must be enabled in the Factory Configuration, before this service
button is active. Pressing it will energize the elctrical solenoid and lower the print head. The Print Head
Lowered sensor will switch on confirming the head has lowered.
Teach Bag Photoeye
– If the bag eye is not detecting the film, the photoeye may need to be taught.
Remove the film from between the eye and the refelector and besure that the top is closed and latched.
Press and Hold this button for at least 2 seconds but less than 5 seconds.
Start Jaw Test Cycle
– This is a test cycle of the Jaw and is used by the assembly personnel to break-in
the Jaw slide. When the button is pressed, the Jaw moves to the Closed Position and dwells there for 0.5
seconds. It then opens to the Pass-Thru Position and dwells there for 0.5 seconds. The cycle runs for 1
hour and records the number of cycles.
Cancel Cycle Test
– Pressing this button stops the test cycle.
Jaw Test Cycle
– Numeric Readout displays the number of Jaw Cycles. Resets when the next Test Cycle
is initiated.
SCREEN NAVIGATION
CONTROLS
3-10