![Pregis 1153-02 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/pregis/1153-02/1153-02_operators-manual_1595293025.webp)
SX™ Operator Manual
©
Original Printed in English
SETTINGS SCREEN
CONTROLS
There are two screens that allow the user to view and change the current bagger settings.
SETTINGS SCREEN 1
Bag Length
This refers to the usable area inside the bag. This is measured from the bottom of the bag to the seal. The
typical setting is 0.5" less than the measured overall bag length. When using sharp bags, enter the length
shown on the box or roll label.
Seal Offset Distance
The offset distance moves the seal point down from the nominal (zero offset) position. At zero offset, the
seal is approximately 0.5 inches below the perforation. The pressure bar will make contact with the filled
bag just below the perforation. As the user adds Seal Offset, the seal moves down.
Feed Speed
This setting adjusts the peak forward web speed in inches per second. The value can be varied from 4 to
30 in/sec.
Seal Dwell
The amount of time the impulse seal wire turns on. High quality seals are accomplished through proper
seal time settings. These settings will vary with the film gauge and material.
Seal Cool
This setting adjusts the delay (in seconds) that occurs prior to opening the pressure bar. This can be used
to allow additional cooling time for the bag seal. Increasing it will slow the machine and increase the bag-
ger cycle time.
Jaw Pass-Thru
The distance the pressure bar and the stripper plate when the Jaw is opened. It can be adjusted from 1.0 –
4.5” of pass-thru.
3-5