SETTING SCREEN 2
Batch Counter
The maintained button turns on the Counter. The numeric entry to the right of the button is the Target Count
setting. This can be adjusted from 2-9999. When the counter is done, the yellow alert banner is displayed
and the bagger cannot cycle until the counter is reset.
Parts Counter
The maintained button turns on the Counter. The numeric entry to the right of the button is the Target Count
setting. This can be adjusted from 1-999. When the counter is done, and the desired number of parts have
been loaded into the opened bag, the bagger will cycle.
Consecutive Bags
The maintained button turns on the Consecutive Bags function. The numeric entry to the right of the button
is the desired number of consecutive bags in the strip. This can be adjusted from 2-20, but is limited to 50.0
inches of total length.
Be sure to change the Bag Length Setting to the measured length of the bag, and use the Seal Offset set-
ting to adjust the desired sealing position for each bag in the strip.
Filler Drop Time
This setting determines the length of time between Filler Done signal and the start of the next bagger cycle.
The delay is too ensure that the product has been delivered into the bag and is below the pressure bar.
This value is adjustable from 0-9.99 seconds.
HPA Bag Open Dwell
When high pressure air (HPA) is connected, the HPA blows a short blast to aid in opening the bag. The
dwell time determines how long the blast lasts. It is adjustable from 0 to 1.0 seconds.
SCREEN NAVIGATION
CONTROLS