For technical questions, please call 1-888-866-5797.
ITEM 59205
SAFETY
SETU
p
Op
ERA
TION
M
AINTENANCE
Functional Description
Specifications
Generator
Output
120 / 240 VAC, 60 Hz
46A at 120V; 23A at 240V
5,500 Running Watts (6,500 Max. Starting Watts)
Electrical Receptacle
Two 3-Prong, duplex NEMA #5-20 120 V GFCI
One 4-Prong, NEMA #L14-30 twistlock 120 V / 240 V
One DC Outlet 12 VDC
Engine
Displacement
301 cc
Engine Type
Horizontal Single Cylinder 4 stroke OHV
Cooling System
Forced air cooled
Fuel
Type
87+ octane stabilizer treated unleaded gasoline
Recommended fill level
7.93 Gallons / 30 Liters
Engine Oil
Type SAE
10W – 30 above 32° F
5W – 30 at 32° F or below
Capacity
1 Quart
Spark Plug
Type
NHSP
®
/ Torch
®
F6TC
Gap
0.028" – 0.031"
Valve Clearance
Intake
0.002" – 0.004"
Exhaust
0.002" – 0.004"
Run Time
@
50% load
Up to 14.5 hr.
Available accessories
Wheel kit (sold separately)
The emission control system for this Generator’s Engine is warranted for standards set by the U.S. Environmental
Protection Agency and by the California Air Resources Board (also known as CARB). For warranty information,
refer to the last pages of this manual.
Components and Controls
Fuel Gauge
(L 14-30R)