Page 17
For technical questions, please call 1-888-866-5797.
ITEM 59205
SAFETY
SETU
p
Op
ERA
TION
M
AINTENANCE
User-Maintenance Instructions
procedures not specifically explained in this manual must
be performed only by a qualified technician.
TO pREVENT SERIOUS INJURY FROM ACCIDENTAL OpERATION:
Turn the power Switch of the Generator to its “OFF” position, wait for the engine to cool, and disconnect
the spark plug cap before performing any inspection, maintenance, or cleaning procedures.
TO pREVENT SERIOUS INJURY FROM EQUIpMENT FAILURE:
Do not use damaged equipment. If abnormal noise, vibration, or excess
smoking occurs, have the problem corrected before further use.
Follow all service instructions in this manual. The engine may fail critically if not serviced properly.
Many maintenance procedures, including any not detailed in this manual, will need to be
performed by a qualified technician for safety. If you have any doubts about your ability to safely
service the equipment or engine, have a qualified technician service the equipment instead.
Cleaning, Maintenance, and Lubrication
Note:
This maintenance schedule is intended solely as a general guide. If performance decreases or if
equipment operates unusually, check systems immediately. The maintenance needs of each piece of equipment
will differ depending on factors such as duty cycle, temperature, air quality, fuel quality, and other factors.
Note:
The following procedures are in addition to the regular checks and maintenance
explained as part of the regular operation of the engine and equipment.
procedure
Before
Each Use
Monthly or
every 20
hr. of use
Every 3 mo. or
50 hr. of use
Every 6 mo. or
100 hr. of use
Yearly or
every 300
hr. of use
Every
2 Years page
Brush off outside of engine
11
Check engine oil level
11
Check air cleaner
11
Change engine oil
18
Clean/replace air cleaner
*
18
Clean Spark Arrestor
19
Check and clean spark plug
19
1. Check/adjust idle speed
2. Check/adjust valve clearance
3. Clean fuel tank, strainer
and carburetor
4. Clean carbon build-up from
combustion chamber
**
–
Replace fuel line if necessary
**
–
*
Service more frequently when used in dusty areas.
**
These items should be serviced by a qualified technician.