SETU
p

Op
ERA
TION

M

AINTENANCE

Using the Generator

Before Starting the Generator Engine

Before starting the engine:

a. 

Follow the Set Up Instructions 

to prepare the Generator.

b. 

Unplug all loads from the Generator.

c. 

Inspect the Generator and engine.

d. 

Fill the engine with the proper 

amount and type of both 

stabilizer-treated fuel and oil.

Basic Generator Use procedure - See 

following pages for specific instructions

1.  Check that the Generator can handle the 

wattage needed to power your products. 

2.  Start the Engine, and allow the Engine and 

Generator to run and warm up for five minutes 

after starting with no electrical load.

3.  With the engine running, test GFCI 

receptacles before each use as follows:

a.  Press Test button on receptacle 

to trip the GFCI device.

b.  The Reset button should extend, cutting 

off electricity to the receptacle.

c.  If above test fails, do not use receptacle 

until it is repaired or replaced.

d.  Press Reset button in for use.

RESET

TEST

RESET

TEST

Reset 

Button

Test 

Button

120 Volt GFCI Receptacle

4.  Plug in products.

5.  When finished using the Generator, 

disconnect all electrical loads.

Note:

 Do not allow Generator to run 

out of fuel with loads attached.  

6.  Turn off the Engine.

7.  Allow the Generator and its Engine to 

completely cool.  Then store the unit in a 

clean, dry, safe location out of reach of 

children and other unauthorized people.

IMpORTANT:

 After starting the engine, allow it to 

run at no load for five minutes with no load after 

each start-up so that the engine can stabilize.

8.  Break-in Period:

a.  Breaking-in the engine will help to ensure 

proper equipment and engine operation.

b.  The operational break-in period will last 

about 3 hours of use.  During this period:

•  Do not apply a heavy load to the equipment.

c.  The maintenance break-in period will last 

about 20 hours of use.  After this period:

•  Change the engine oil.

Under normal operating conditions 

subsequent maintenance follows the schedule 

explained in the SERVICE section.

Содержание 59205

Страница 1: ...intenance and cleaning procedures Write the product s serial number in the back of the manual or month and year of purchase if product has no number Keep this manual and the receipt in a safe and dry...

Страница 2: ...e use of a special tool or lock and key or other means of security and shall be controlled by the authority responsible for the location 2 Gasoline fuel and fumes are flammable and potentially explosi...

Страница 3: ...de sensor malfunction Sensor needs service Do not use the Generator until the sensor is working properly For technical questions please call 1 888 866 5797 Note Yellow light flashes once after startin...

Страница 4: ...e the Generator on transport vehicles to prevent the tool from rolling slipping and tilting 23 Industrial applications must follow OSHA requirements 24 Do not leave the Generator unattended when it is...

Страница 5: ...ion Do not modify the generator or its engine and do not use the generator for a purpose for which it is not intended 43 Extension Cord Make sure your extension cord is in good condition When using an...

Страница 6: ...dable or missing contact Harbor Freight Tools for a replacement 8 Have the equipment serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of th...

Страница 7: ...ooled Fuel Type 87 octane stabilizer treated unleaded gasoline Recommended fill level 7 93 Gallons 30 Liters Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 Quart Spark Plug Ty...

Страница 8: ...or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects the Generator from...

Страница 9: ...pure sine wave generators Wheel Kit 64788 sold separately can be used with this Generator Grounding The Generator must be properly grounded in accordance with all relevant electrical codes and standar...

Страница 10: ...a bowl under the fuel cup to catch any spilled fuel 5 Unthread the screws holding the solenoid in place CAUTION Carburetor bowl may have gas in it which will leak upon removing the solenoid bolt 6 Dis...

Страница 11: ...t threading it in and remove it to check the oil level The oil level should be up to the full level as shown above 5 If the oil level is at or below the low mark add the appropriate type of oil until...

Страница 12: ...If above test fails do not use receptacle until it is repaired or replaced d Press Reset button in for use RESET TEST RESET TEST Reset Button Test Button 120 Volt GFCI Receptacle 4 Plug in products 5...

Страница 13: ...tly until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do not let the Starter Handle snap back against the engine Hold it as it recoils...

Страница 14: ...er exceed the rated capacity for this Generator as serious damage to the Generator and or appliances tools and equipment could result from an overload Starting and running wattage requirements should...

Страница 15: ...r that only supplies the exact watts needed To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed...

Страница 16: ...engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the Generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before turning off...

Страница 17: ...qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment o...

Страница 18: ...ug 4 Remove the drain plug and if possible tilt the crankcase slightly to help drain the oil out Recycle used oil 5 Replace the drain plug and tighten it 6 Clean the top of the Dipstick and the area a...

Страница 19: ...lace immediately after cleaning and before further operation Long Term Storage When the equipment is to remain idle for longer than 20 days prepare the Engine for storage as follows 1 CLEANING Wait fo...

Страница 20: ...posure to rain and sunlight NOTICE During extended storage periods the Engine must be started every 3 months and allowed to run for 15 20 minutes or the Warranty is VOID 5 AFTER STORAGE Before startin...

Страница 21: ...mber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Power Switch at OFF position 2 Spark plug cap not connected securely 3 Spark plug electrode wet...

Страница 22: ...y operate generator outside 2 Carbon monoxide sensor malfunction Sensor needs service Call 1 888 866 5797 as soon as possible Do not use the Generator until the sensor is working properly 3 Make sure...

Страница 23: ...nosing or servicing the equipment or engine Troubleshooting continued PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS M...

Страница 24: ...8 Bolt 3 49 Seal Oil 1 50 Plug Rubber 1 51 Protector Oil 1 52 Bolt 1 53 Arm Governor 1 54 Washer Flat 1 55 Pin 1 56 Spring Throttle Valve Returning 1 57 Rod Governor 1 Part Description Qty 58 Support...

Страница 25: ...n Engine Frame Right 2 135 Nut 4 136 Jacket Rubber 2 137 Cushion Engine Frame 2 Part Description Qty 138 Frame Assy Engine 1 139 Grounding 1 140 Washer Serrated Lock External Teeth 1 141 Nut 6 142 CO...

Страница 26: ...44 46 47 38 37 51 50 49 41 48 39 52 53 54 55 59 60 58 56 57 61 62 63 64 65 66 68 69 70 71 72 73 67 75 74 77 78 74 76 79 80 80 81 81 82 83 84 85 86 88 89 90 91 87 93 92 94 95 96 98 97 99 98 109 102 101...

Страница 27: ...the emissions control system on your engine will be free from defects in material and workmanship for two 2 years provided there has been no improper maintenance misuse or abuse of your engine Your e...

Страница 28: ...26677 Agoura Road Calabasas CA 91302 1 888 866 5797...

Отзывы: