Rewire the AMT
Remove the front and side access covers to provide sufficient space to install the
console cables.
IMPORTANT
Before continuing with the following procedure, be sure to remove any ties or
other materials that hold the side arms in place before the supports are installed.
To thread the new cables through the equipment:
2
Step
Procedure
Lift the moisture seal upward and remove it from the center column.
Extend a finger through the moisture seal opening and under the
front edge of the top cover on one side. While pressing upward on
the top cover, use the heel of your palm to tap gently below its front
edge and release it. Repeat this step to release the other side of the
top cover.
While holding the front edge of the top cover up, use the palm of
your other hand to tap gently just below the cover's back edge. Lift
the cover up and out of the way.
Remove the two screws at the bottom corners of the front cover.
Gently press in on each of the side covers, just behind the front edge
and about 8 inches from the bottom, while pulling the front cover
assembly forward to disengage it. Move the front cover assembly
forward and slightly upward to remove it.
Note Each side cover has a small triangular mark to show you where
to press.
N/A
Thread the PVS power and television cables through the center
column and guide them through the opening at the bottom.
Important The cables must be secured in the cable retainers attached to
the frame. They must then pass through the square opening in the jack
panel.
Guide the arm openings in the front cover around the arms of the
AMT, taking care that the tabs at the bottom corners of both
openings are inside the two side covers, then guide the front cover
until the latches on the side covers click into place. Reattach the two
screws at the bottom corners of the front cover. Fully tighten the
screws.
N/A
Important In the following step, do not apply excessive force to seat the
cover.
Position the rear edge of the top cover so that the clips on the top
and back covers are engaged securely. Gently snap the front edge of
the top cover into place. Use the palm of your hand if necessary.
N/A
Wrap the moisture seal around the center column below the heart
rate sensor grips, then fit it into the top cover. Make sure that the
surfaces and edges of the moisture seal are flush with those on the
top cover.
9