
C844 Upright Cycle
Page 39
Procedure 7.6 - Replacing the Input Filter Assembly (240-Volt
Units Only)
WARNING
Always turn off the C844 with the ON/OFF switch and unplug the power cord from the wall outlet
before you service the cycle.
1.
Place the C844 Cycle on its front end. Remove the pan from the base of the cycle.
2.
Disconnect the wires that are connected to the input filter assembly.
3.
Remove the fasteners that secure the input filter assembly to the cycle frame.
4.
Position the new filter assembly at its mounting location.
5.
Install the connectors that secure the filter assembly to the cycle frame.
6.
Connect the wires removed in Step 2 to the new input filter assembly.
7.
Install the pan on the base of the cycle. Return the cycle to its upright position.
8.
Plug the power cord into the power entry module.
9.
Check the cycle operation as described in Section Four.
Содержание C844
Страница 15: ...C844 Upright Cycle Page 15 Diagram 5 1 Adjusting the gap between the flywheel and magnet assembly ...
Страница 17: ...C844 Upright Cycle Page 17 Diagram 5 2 C844 Magnet Wiring ...
Страница 19: ...C844 Upright Cycle Page 19 Diagram 5 3 The Upper and Lower Couplers ...
Страница 36: ...C844 Upright Cycle Page 36 Diagram 7 3 C844 Wiring Diagram 120Vac Units ...