ProtEX-MAX PD8-6310-WM Explosion-Proof NTEP Certified Batch Controller Instruction Manual
31
Display
Parameter Action/Setting
Description
Altern
Alternate
2
Set relay for pump
alternation control
(relays assigned to
rate)
2
Sampl
Sampling
Set relay for sampling
operation (rate or GT)
OFF
Off
Disable relay and front
panel status LED
(Select Off to enable
Interlock feature)
Preset
Preset
Set batch preset
Set 1
Set 1
Program set point 1
RSt 1
Reset 1
Program reset point 1
RLY 2
Relay 2
Relays 2-4 setup.
FaiLSF
Fail-safe
Enter
Fail-safe
menu
FLS 1
Fail-safe 1
Set relay 1 fail-safe
operation
on
On
Enable fail-safe
operation
off
Fail-safe
off
Disable fail-safe
operation
DeLAY
Delay
Enter relay
Time Delay
menu
DLY 1
Delay 1
Enter relay 1 time delay
setup
On 1
On
Set relay 1 On time
delay
OFF 1
Off
Set relay 1 Off time
delay
Aout
Analog
output
Enter the
Analog output
scaling menu
Dis 1
Display 1
Program display 1 value
Out 1
Output 1
Program output 1 value
(e.g. 4.000 mA)
Dis 2
Display 2
Program display 2 value
Out 2
Output 2
Program output 2 value
(e.g. 20.000 mA)
reset
Reset
Press Enter to access
the
Reset
menu
Rst Hi
Reset high
Press Enter to reset
max display
Display
Parameter Action/Setting
Description
Rst Lo
Reset low
Press Enter to reset min
display
Rst HL
Reset
high & low
Press Enter to reset
max & min displays
Rst t
Reset total
Press Enter to reset
total
Rst Gt
Reset
grand total
Press Enter to reset
grand total
Rst bc
Reset
batch
count
Press Enter to reset
batch count
Contrl
Control
Enter
Control
menu
Auto
Automatic
Press Enter to set
controller for automatic
operation
mAn
Manual
Press Enter to manually
control relays or analog
output operation
`pass
Password
Enter the
Password
menu
Pass 1
Password
1
Set or enter Password 1
Pass 2
Password
2
Set or enter Password 2
Pass 3
Password
3
Set or enter Password 3
Total
Total
password
Set or enter password
for manual reset
Gtotal
Grand total
password
Set or enter password
for manual reset
nonrst
Non-
resettable
Non-resettable grand
total set after entering
“050873” for Gtotal
password
unloc
Unlocked
Program password to
lock controller
locd
Locked
Enter password to
unlock controller
999999
-99999
Flashing
display
Overrange condition
Underrange condition
1.
During operation, only the STOP button will function, to stop/pause the batch. As a result, relay alarms
cannot be manually reset.
2.
This setting used for level control applications. It is not appropriate if using this controller for batching
applications.