ProtEX PD8-6080/PD8-6081 Explosion-Proof Modbus
®
Scanner Instruction Manual
59
Advanced Features Menu & Display Messages
Display
Parameter
Action/Setting
sCan
Scan
Enter
Scan
menu
mode
Scan Mode
Select Auto or Manual
Scan Mode
Auto
Automatic
Select Automatic Scan
Mode
time
Scan Time
Select Scanning Time
man
Manual
Select Manual Scan Mode
Alarm
Alarm
Select Go or Stop Alarm
go
Go
Select Alarm Go
Stop
Stop
Select Alarm Stop
Contrl
Control
Enter
Control
menu for
relays and analog output
1
Auto
Automatic
Select Automatic Control
of Outputs and Relays
man
Manual
Select Manual Control of
Outputs and Relays
Aout 1
Analog
Output 1
Select Analog Output 1
for manual control
rly 1
Relay 1
Select Relay 1-4 for
manual control
on
On
Select
On
for Relay 1-8
off
Off
Select
Off
for Relay 1-8
filter
Filter
Enter
Filter
menu
Pv 1
PV 1 Filter
Program Filter Value for
PV 1
Pv 2
PV 2 Filter
Program Filter Value for
PV 2
bypass
Filter Bypass
Enter
Filter Bypass
menu
Pv 1
PV 1 Filter
Bypass
Program Filter Bypass
Value for PV 1
Pv 2
PV 2 Filter
Bypass
Program Filter Bypass
Value for PV 2
round
Rounding
Feature
Enter
Rounding Feature
menu
1
*
1 Rounding
Value
Program Rounding Value
for PV
*(User-selectable &
rounds to the nearest 1, 2,
5, 10, 20, 50, 100)
select
Select
Enter
Select
menu
functn
Function
Enter data
Linearization
Function
menu
Pv 1
*
PV 1
Function
*Enter
Linearization
Function
menu for all
enabled PVs
Ch C1
*
Ch C1
Function
*Enter
Linearization
Function
menu for all
enabled math channels
Linear
Linear
Enter
Linear
menu
No pts
Number of
Points
Enter
Number of
Linearization Points
sCale
Scale
Scale
Number of
Linearization Points
Inp 1
Input 1
Calibrate input 1 signal or
program input 1 value
Dis 1
Display 1
Program display 1 value
Inp 2
Input 2
Calibrate input 2 signal or
program input 2 value (up to 32
points for PV1 & PV2)
Display
Parameter
Action/Setting
Dis 2
Display 2
Program display 2 value (up
to 32 points for PV1 & PV2)
square
Square Root
Enter
Square Root
menu
Prog e
Programmable
Exponent
Enter
Programmable
Exponent
menu
1.5000
Programmable
Exponent
Value
Enter the Programmable
Exponent Value
rht
Round
Horizontal
Tank
Enter
Round Horizontal
Tank
menu
Inch
Inch
Enter to calculate tank
values in Inches
cm
Centimeters
Enter to calculate tank
values in Centimeters
diamr
Diameter
Enter tank diameter
Length
Length
Enter tank length
math
Math
Enter
Math
menu
Ch C1
*
Channel C1
*Enter
Math Channel
C1-C4
menu
Opertn
Operation
Enter
Math Operation
menu
Const
Constant
Enter
Math Constant
menu
Adder
Adder
Enter
Adder Value
FACtr
Factor
Enter
Factor Value
sum
Sum
Math Function
Sum
dif
Difference
Math Function
Difference
difabs
Absolute
Difference
Math Function
Absolute
Difference
avg
Average
Math Function
Average
multi
Multiply
Math Function
Multiply
divide
Divide
Math Function
Divide
Hi-pv
Max
Math Function
Maximum
of all selected PVs
Lo-pv
Min
Math Function
Minimum
of all selected PVs
dra
uw
Draw
Math Function
Draw
uw
avg
Weighted
Average
Math Function
Weighted
Average
ratio
Ratio
Math Function
Ratio
Concen
Concentration
Math Function
Concentration
math2
Math2
Resultant Math
Channel
Math operation applied
to other math channels
(e.g. C3 = C1/C2)
sum
Sum
Math2 Function
Sum
dif
Difference
Math2 Function
Difference
difabs
Absolute
Difference
Math2 Function
Absolute
Difference
avg
Average
Math2 Function
Average
multi
Multiply
Math2 Function
Multiply
divide
Divide
Math2 Function
Divide
Cutoff
Cutoff
Enter
Low Flow Cutoff
menu
Pv 1
PV 1 Cutoff
Program Cutoff Value for
PV 1