Helios Large Display Analog Input Batch Controller Instruction Manual
PD2-6210
6
Fuse
Required external fuse: UL
Recognized, 5 A max, slow blow;
up to 6 controllers may share one
5 A fuse
Normal Mode
Rejection
Greater than 60 dB at 50/60 Hz
Isolation
4 kV input/output-to-power line;
500 V input-to-output or output-to-
P+ supply
Overvoltage
Category
Installation Overvoltage Category
II:
Local level with smaller transient
overvoltages than Installation
Overvoltage Category III.
Environmental
Operating temperature range: -40
to 150°F (-40 to 65°C)
Storage temperature range: -40 to
185°F (-40 to 85°C)
Relative humidity: 0 to 90% non-
condensing
Connections
Removable and integrated screw
terminal blocks accept 12 to 22
AWG wire.
Enclosure
UL Type 4X, IP65 rated.
Polycarbonate & glass blended
plastic case, color: gray. Includes
four PG11 through-hole conduit
openings, with two factory installed
PG11, IP68, black nylon threaded
hole plugs with backing nuts.
Mounting
Wall Mounting:
Four (4) mounting
holes provided for screwing
controller into wall. See Wall
Mounting Instructions on page 11
for additional details.
Pipe Mounting:
Optional pipe
mounting kit (PDA6260) allows for
pipe mounting. Sold separately.
See Pipe Mounting Instructions on
page 12 for additional details.
Tightening
Torque
Removable Screw Terminals:
5
lb-in (0.56 Nm)
Digital I/O and RS485 Terminals:
2.2 lb-in (0.25 Nm)
Overall
Dimensions
10.63" x 12.59" x 4.77" (270 mm x
319.7 mm x 121.2 mm) (W x H x
D)
Weight
6.10 lbs (2.76 kg)
Warranty
3 years parts & labor
Process Input
Inputs
Field selectable: 0-20, 4-20 mA,
10 V (0-5, 1-5, 0-10 V), Modbus
PV (Slave)
Accuracy
±0.03% of calibrated span ±1
count,
square root & programmable
exponent accuracy
range: 10-100% of calibrated span
Temperature
Drift
0.005% of calibrated span/
C max
from 0 to 65
C ambient,
0.01% of calibrated span/
C max
from -40 to 0
C ambient
Signal Input
Conditioning
Linear, square root, programmable
exponent, or round horizontal tank
volume calculation
Multi-Point
Linearization
2 to 32 points
Programmable
Exponent
1.0001 to 2.9999
Round H Tank
Diameter & Length: 999.999 inch
or cm calculates volume in gallons
or liters respectively.
Low-Flow Cutoff
0-999999 (0 disables cutoff
function)
Decimal Point
Up to five decimal places or none:
d
.
ddddd
,
d
.
dddd
,
d
.
ddd
,
d
.
dd
,
d
.
d
,
or
dddddd
Calibration
Range
Input Range Minimum Span Input
1 & Input 2
4-20 mA
0.15 mA
10 V
0.01 V
An error message will appear if the
input 1 and input 2 signals are too
close together.
Input Impedance
Voltage ranges: greater than 500
k
Current ranges: 50 - 100
(depending on resettable fuse
impedance)
Input Overload
Current input protected by
resettable fuse, 30 VDC max.
Fuse resets automatically after
fault is removed.
F4 Digital Input
Contacts
3.3 VDC on contact. Connect
normally open contacts across F4
to COM.
F4 Digital Input
Logic Levels
Logic High:
3 to 5 VDC;
Logic
Low:
0 to 1.25 VDC
Batch Controller Rate/Totalizer Display
Rate Display
Indication
-99999 to 999999, lead zero
blanking. “R” LED illuminates while
displaying rate.
Batch Total &
Grand Total
Display
0 to 999,999; automatic lead zero
blanking. “T” LED is illuminated
while displaying batch total. “GT”
LEDs are illuminated while
displaying grand total. Up to
999,999 for batch total/preset. Up to
999,999,999 with grand total-
overflow feature. “
oF
” is displayed
to the left of grand total overflow
and ▲ LED is illuminated.
Batch Total
Decimal Point
Up to five decimal places or none:
d
.
ddddd
,
d
.
dddd
,
d
.
ddd
,
d
.
dd
,
d
.
d
,
or
dddddd
Total decimal point is independent
of rate decimal point.