PD2-6210
Helios Large Display Analog Input Batch Controller Instruction Manual
51
Display
Parameter
Action/Setting
Count
Count
Set total and grand total count direction
Tot C
Total Count
Set total to count up or down
Gtot C
Grand Total Count
Set grand total to count up or down
C Strt
Count Start
Set start for total or grand total countdown
AoutPr
Analog output
programming
Program analog output parameters
Source
Source
Select source for the 4-20 mA output
O-rang
Overrange
Program mA output for display overrange
u-rang
Underrange
Program mA output for display underrange
break
Break
Set input break condition operation
Force
Force
Force analog output value for loop break
Ignore
Ignore
Ignore loop break condition
mAx
Maximum
Program maximum mA output allowed
min
Minimum
Program minimum mA output allowed
Calib
Calibrate
Calibrate 4-20 mA output (internal reference source used for
scaling the output)
4 mA
4 mA output
Enter mA output value read by milliamp meter with at least
0.001 mA resolution
20 mA
20 mA output
Enter mA output value read by milliamp meter with at least
0.001 mA resolution
user
User I/O
Assign function keys and digital I/O
F1
F1 function key
Assign F1 function key
F2
F2 function key
Assign F2 function key
F3
F3 function key
Assign F3 function key
F4
F4 function
Assign F4 function (digital input)
dI I
Digital input 1
Assign digital input 1 – 4, if expansion modules are connected
dO 1
Digital output 1
Assign digital output 1 – 4, if expansion modules are connected
ICal
Internal source
calibration
Enter internal source calibration (used for scaling the meter
without a signal source)
C CAL
Current calibration
Calibrate 4-20 mA current input (internal reference source used
for scaling the input)
C lo
Current low
Calibrate low current input (e.g. 4 mA)
C Hi
Current high
Calibrate high current input (e.g. 20 mA)
v CAL
Voltage calibration
Calibrate voltage input
v Lo
Voltage low
Calibrate low voltage input (e.g. 0 V)
v Hi
Voltage high
Calibrate high voltage input (e.g. 10 V)
Diag
Diagnostics
Display parameter settings
LED t
LED test
Test all LEDs
Info
Information
Display software and S/N information
Erase
Erase
Delete the MeterView Pro installation files from the meter
www.calcert.com
1.888.610.7664
0
5
10
15
20
25
30