PD8-6300 Pulse Input Rate/Totalizer, Counter & Tachometer
Instruction Manual
36
Setting Up the Rate/Totalizer
Meter (
setup
)
The
Setup
menu is used to select:
1. Enable or disable totalizer features
2. Units for Rate, Total, and Grand Total
3. Decimal point position
4. Input Calibration
5. Display parameter and intensity
6. Relay operation
7. 4-20 mA analog output scaling
Press the Enter button to access any menu or press
Up arrow button to scroll through choices. Press the
Menu button to exit at any time.
Setting the Input Signal (
Input
)
There is a switch, located to the right of the input
connector, which must be configured according to the
input level and type. For location of this switch, see
on page
Jumper J4 located inside the meter, behind the input
signal connector, is used to select the excitation
voltage (24 V [Default setting], 10 V or 5 V) which is
supplied to the P+ and P- wiring terminals. For
location of this switch, see
Enter the Input menu to enable or disable the totalizer
features.
Setting the Totalizer Features
(
total
)
Enable or disable the totalizer features by selecting
“
Yes
” or “
no
” after the input type has been set up. If
the totalizer features are disabled, most totalizer
features and functions are hidden from the menus.
Note:
The totalizer continues working in the background.