PDW90 Point to Multi-Point Wireless Instruction Manual
8
General Specifications
Wireless Radio
Frequency
900 MHz
Range
500 ft (152.4 m) indoor, 1 mi
(1.61 km) outdoor (line-of-sight)
Encryption
AES 128-bit encryption available us-
ing PDW Manager software
Interference
Reduction
Frequency Hopping Spread
Spectrum (FHSS)
Power Output
24 dBm (250 mW)
Sensitivity
-101 dBm
PDW Manager Software
System
Requirements
Microsoft
®
Windows
®
XP/Vista/7/8/10
Communica-
tions
USB 2.0 (Standard USB A to Micro
USB B)
Configuration
Configure devices one at a time
RS-485 Modbus
®
RTU Serial Comms
Compatibility
EIA-485
Connectors
Removable screw terminal connector
Max Distance
3,937' (1,200 m) max
Baud Rate
1200 – 57,600 bps
Data
8 bit (1 start bit, 1 or 2 stop bits)
Parity
Even, Odd, or None with 2 stop bits
Modbus
Timeout
0.5, 1, 2, 3, 4, 5 seconds;
user selectable
Safety Information
Caution
:
Read complete instructions
prior to installation and operation of the
device.
Warning
:
Read all product labels
completely and follow all instructions
and requirements listed on the labels
for installation or service.
Warning!
Installation and service should be performed only by trained ser-
vice personnel. Service requiring replacement of internal compo-
nents must be performed at the factory.
Installation
Base Station:
All wiring connectors are accessed by opening the enclosure. To access electrical
connectors, unclasp enclosure and open.
Field Units:
All pushbuttons and wiring connectors are accessed by opening the enclosure. To
access electrical connectors, remove the 2 captive screws and remove the display assembly.
Unpacking
Remove both units from box. Inspect the packaging and contents for damage. Report damages, if
any, to the carrier. If any part is missing or the units malfunction, please contact your supplier or
the factory for assistance.
!
www.
.com
1.800.561.8187