PD6928 Ex-Proof & I.S. Loop-Powered Flow Rate/Totalizer
Instruction Manual
17
On-Board Digital Input
Function
Remote operation of front-panel buttons,
acknowledge/reset relays, reset total, reset
max/min values, etc. See User section of
on page
for a complete list of capabilities.
Contacts
2.1 VDC on contact. Connect normally open
contacts across DI+ and DI-
Logic Levels
Logic High: 2.4 to 30 VDC (max)
Logic Low: 0 to 0.9 VDC
MeterView XL Software
Availability
Free download from
System
Requirements
Microsoft
®
Windows
®
7 & 10
Communicati
ons
USB 2.0 (Standard USB A to Micro USB B)
Cable provided
Configuration
Configure all parameters on the meter.
Configure meters one at a time.
Configuration
Files
Generate with or without meter connected;
Save to file for later use.
USB Power
Connection
Meter is powered by USB connection during
programming, if 4-20 mA loop is not
connected.
•
The meter should only be connected to a
computer while it is located in a safe area.
To download the latest MeterView XL programming
software and manual, visit