PD2-6060
Helios Large Display Dual-Input Meter Instruction Manual
5
Ordering Information
Standard Models
85-265 VAC Model 12-24 VDC Model Options Installed
PD2-6060-6H0
PD2-6060-7H0
No Options
PD2-6060-6H7
PD2-6060-7H7
4 relays & 4-20 mA output
Accessories
Model
Description
PDA1011
Dual 4-20 mA expansion module
PDA6260
Pipe Mounting Kit
PDA7485-I
RS-232 to RS-422/485 isolated converter
PDA7485-N
RS-232 to RS-422/485 non-isolated converter
PDA8485-I
USB to RS-422/485 isolated converter
PDA8485-N
USB to RS-422/485 non-isolated converter
PDAPLUG2
Plastic Conduit Plug
PDX6901
Suppressor (snubber): 0.01 µF/470
, 250 VAC
Specifications
Except where noted all specifications apply to operation at +25°C.
General
Display
Main display: 1.8" (46 mm) high, red
LEDs
6 digits per line (-99999 to 999999), with
lead zero blanking
Display
Intensity
Eight user selectable intensity levels
Display
Update Rate
5/second (200 ms)
Overrange
Display flashes
999999
Underrange
Display flashes
-99999
Display
Assignment
Display lines 1 & 2 may be assigned to
process values for Channels A (Ch-A), B
(Ch-B), or C (Ch-C), toggle between
(Ch-A & Ch-B, Ch-A & Ch-C, Ch-B &
Ch-C, and Ch-A, Ch-B, & Ch-C), toggle
between Channel & units, show channel
gross value (no tare) or toggle net (tare)
and gross values, show relay set points,
max & min values, or Modbus input. The
lower display may also be set to show
engineering units or be off, with no
display.
Programming
Methods
Four programming buttons, digital inputs,
PC and MeterView Pro software, or
Modbus registers.
Noise Filter
Programmable from 2 to 199 (0 will
disable filter)
Filter Bypass
Programmable from 0.1 to 99.9% of
calibrated span
Recalibration
All ranges are calibrated at the factory.
Recalibration is recommended at least
every 12 months.
Max/Min
Display
Max/min readings reached by the
process are stored until reset by the
user or until power to the meter is turned
off.
Password
Three programmable passwords restrict
modification of programmed settings.
Pass 1: Allows use of function keys and
digital inputs
Pass 2: Allows use of function keys,
digital inputs and editing set/reset points
Pass 3: Restricts all programming,
function keys, and digital inputs.
Power Options
85-265 VAC 50/60 Hz, 90-265 VDC, 20
W max
or
12-24 VDC
10%, 15 W max
Powered over USB for configuration only.
Isolated
Transmitter
Power Supply
Terminals P+ & P-: 24 VDC
10%. 12-24
VDC powered models selectable for 24, 10,
or 5 VDC supply (internal P+/P- switch).
85-265 VAC models rated @ 200 mA max,
12-24 VDC powered models rated @ 100
mA max, @ 50 mA max for 5 or 10 VDC
supply.
Non-Volatile
Memory
All programmed settings are stored in
non-volatile memory for a minimum of
ten years if power is lost.
Fuse
Required external fuse: UL Recognized,
5 A max, slow blow; up to 6 meters may
share one 5 A fuse
Normal Mode
Rejection
Greater than 60 dB at 50/60 Hz
www.
GlobalTestSupply
.com
Find Quality Products Online at: