Alarm inputs, switch and splitter
2.6.9
These are used by the switch and splitter modules ALARM LEFT and ALARM RIGHT
Load
10Kohms pulled up to +5V
Inputs conditions
OKAY condition < 100 ohms to ground
ALARM condition > 100Kohms to ground
No damage voltage
-0.5 to +5.5V
RF connectors
2.6.10
Maximum RF input power, no damage
see rating in section 6 or contact
ViaLite Communication
Maximum RF output power
see rating in section 6, or contact
ViaLite Communication
Optical connections
2.6.11
Maximum usable input power
see rating in section 6 or contact
ViaLite Communication
Optical output power
see rating in section 6 or contact
ViaLite Communication