Technical specification, Splitter, Wideband
6.1.2
Units
Wideband 50 ohms
without DC path
Wideband 50 ohms
with DC path
Module
HRD-1-S1-0R-01
HRD-2-S1-0R-41
Frequency range
MHz
10-3000
Impedance, RF
connector
50Ω SMA
VSWR
(typ)
k
1:1.5
MHz
10-1000
1000
–
2500
2500-3000
10-1000
1000
–
2500
2500-3000
Insertion loss, path S1,
port A-B
dB (typ)
k
3.9
4.4
5.3
4.8
5.5
6.0
Insertion loss, path S2,
port C-B
dB (typ)
k
3.9
4.3
5.2
4.8
5.5
5.5
Flatness, fullband
dB (typ)
±0.9
Insertion loss, path S1,
port A-B
dB (max)
4.5
5.0
6.0
5.3
6.0
6.5
Insertion loss, path S2,
port C-B
dB (max)
4.5
5.0
6.0
5.3
6.0
6.5
Isolation, port A-C
dB (typ)
20
20
18
20
20
18
Maximum input Signal
dBm
+24
DC pass though,
maximum current
A
No DC pass through
0.8
DC pass though,
maximum Voltage
V
25
Power
W (max)
0.4
Summary Alarm output
Open drain alarm: OPEN: Okay, CURRENT SINK: Alarm
Operating temperature
range
-10°C to +50°C
Storage temperature
range
-40°C to +70°C
All tests @ 25°C after 15 minutes warm
up
k
Measured @ midband