HRS-HB-9
S
UPPORT
M
ODULE
H
ANDBOOK
.
DOCX
54
Technical specification, 3 port switch
6.2
Technical specification, 3 port switch, L-Band HTS, high isolation
6.2.1
Units
L-Band HTS 50
ohms
without DC path
L-Band HTS 50
ohms
with DC path
L-Band HTS 75
ohms
Module
HRS-1-L1-0R-01
HRS-4-L1-0R-41
HRS-1-L3-0R-01
Frequency range
MHz
700-2450
Impedance, RF connector
50Ω SMA
50Ω SMA
75Ω BNC
VSWR
(typ)
k
1:1.5
Insertion loss, LEFT, port A-B
dB (typ)
k
1.8
2.3
2.7
Insertion loss, RIGHT, port C-B
dB (typ)
k
1.8
2.3
2.7
Flatness, fullband
dB (typ)
±0.3
±0.4
±0.5
Insertion loss, LEFT, port A-B
dB
(max)
k
2.5
3
3.5
Insertion loss, RIGHT, port C-B
dB
(max)
k
2.5
3
3.5
Isolation, port A-C
dB (typ)
60
60
45
Maximum input Signal
dBm
+24
DC pass-through current
A
No DC path
0.8
No DC path
Switching speed
uS (typ)
15
Power
W (max)
0.4
Summary Alarm output
Open drain alarm: OPEN: Okay, CURRENT SINK: Alarm
Operating temperature range
-10°C to +50°C
Storage temperature range
-40°C to +70°C
All tests @ 25°C after 15 minutes warm up
k
Measured @ 1.2GHz