PPA DZ RIO 350 JET FLEX Скачать руководство пользователя страница 3

4

5

TECHNICAL CHARACTERISTICS

DZ RIO BRUSHLESS 400 / DZ RIO BRUSHLESS 700 

AUTOMATION TYPE

Sliding

Sliding

MODEL

BRUSHLESS-400

BRUSHLESS-700

NOMINAL VOLTAGE

220 V / 127 V

220 V / 127 V

NOMINAL FREQUENCY

60 Hz

60 Hz

NOMINAL POWER

50 W / 230 W

130 W / 150 W

ENGINE RPM

4500 RPM

4500 RPM

NOMINAL CURRENT

0.7 A/2,8A

0,7 A / 2,0 A

REDUCTION

01:23

01:23

LINEAR VELOCITY

25 m/min (Z14)

32 m/min (Z18)

25 m/min (Z14)

32 m/min (Z18)

MANEUVER

100 cycles/h

100 cycles/h

LEVEL OF PROTECTION

IPX4

IPX4

TEMPERATURE RANGE

-5° C / +50° C

-5° C / +50° C

TYPE OF INSULATION

CLASS B, 130° C

CLASS B, 130° C

TRAVEL STOP

Hybrid

Hybrid

MAxIMUM GATE LEAF MASS

400 Kg

700 Kg

MAxIMUN GATE DIMENSION

HEIGHT = 2,5 m

LENGTH = 3,0 m

HEIGHT = 2,5 m

LENGTH = 3,0 m

DZ RIO 400 / DZ RIO 400 JET FLEX

AUTOMATION TYPE

Sliding

Sliding

Sliding

MODEL

Single-phase

Single-phase

Jet Flex

NOMINAL VOLTAGE

220 V

127 V

220 V / 127 V

NOMINAL FREQUENCY

60 Hz

60 Hz

60 Hz

NOMINAL POWER

515 W

370 W

390 W / 345 W

ENGINE RPM

1740 RPM

1740 RPM

4365 RPM

NOMINAL CURRENT

2,25 A

3,1 A

2,75 A / 3,6 A

REDUCTION

1:23

1:23

1:23

LINEAR VELOCITY

17,1 m/min (Z18)

13,3 m/min (Z14)

17,1 m/min (Z18)

13,3 m/min (Z14)

42,9 m/min (Z18)

33,0 m/min (Z14)

MANEUVER

30 cycles/h

30 cycles/h

40 cycles/h

LEVEL OF PROTECTION

IPX4

IPX4

IPX4

TEMPERATURE RANGE

-5° C / +50° C

-5° C / +50° C

-5° C / +50° C

TYPE OF INSULATION

Class B, 130° C

Class B, 130° C

Class B, 130° C

TRAVEL STOP

Analogic / Digital

Analogic / Digital

Hybrid

MAxIMUM GATE LEAF MASS

400 Kg

400 Kg

400 Kg

MAxIMUN GATE DIMENSION

HEIGHT = 2,5 m 

LENGTH = 3,0 m

HEIGHT = 2,5 m 

LENGTH = 3,0 m

HEIGHT = 2,5 m 

LENGTH = 3,0 m

DZ RIO 500 / DZ RIO 500 JET FLEX

AUTOMATION TYPE

Sliding

Sliding

Sliding

MODEL

Single-phase

Single-phase

Jet Flex

NOMINAL VOLTAGE

220 V

127 V

220 V / 127 V

NOMINAL FREQUENCY

60 Hz

60 Hz

60 Hz

NOMINAL POWER

286 W

300 W

285 W / 415 W

ENGINE RPM

1740 RPM

1740 RPM

4365 RPM

NOMINAL CURRENT

2,35 A

3,05 A

2,35 A / 3,65 A

REDUCTION

1:23

1:23

1:23

LINEAR VELOCITY

17,1 m/min (Z18)

13,3 m/min (Z14)

17,1 m/min (Z18)

13,3 m/min (Z14)

42,9 m/min (Z18)

33,0 m/min (Z14)

MANEUVER

40 cycles/h

40 cycles/h

50 cycles/h

LEVEL OF PROTECTION

IPX4

IPX4

IPX4

TEMPERATURE RANGE

-5° C / +50° C

-5° C / +50° C

-5° C / +50° C

TYPE OF INSULATION

Class B, 130° C

Class B, 130° C

Class B, 130° C

TRAVEL STOP

Analogic / Digital

Analogic / Digital

Hybrid

MAxIMUM GATE LEAF 

MASS

500 Kg

500 Kg

600 Kg

MAxIMUN GATE 

DIMENSION

HEIGHT = 2,5 m 

LENGTH = 3,0 m

HEIGHT = 2,5 m 

LENGTH = 3,0 m

HEIGHT = 2,5 m 

LENGTH = 3,0 m

DZ RIO 350 JET FLEX

AUTOMATION TYPE

Sliding

MODEL

Jet Flex

NOMINAL VOLTAGE

220 V / 127 V

NOMINAL FREQUENCY

60 Hz

NOMINAL POWER

280 W / 340 W

ENGINE RPM

5800 RPM

NOMINAL CURRENT

2,5 A / 2,4 A

REDUCTION

1:23

LINEAR VELOCITY

42,9 m/min (Z18)

33,0 m/min (Z14)

MANEUVER

30 cycles/h

LEVEL OF PROTECTION

IPX4

TEMPERATURE RANGE

-5° C / +50° C

TYPE OF INSULATION

Class B, 130° C

TRAVEL STOP

Hybrid

MAxIMUM GATE LEAF MASS

350 Kg

MAxIMUN GATE DIMENSION

HEIGHT = 2,5 m 

LENGTH = 3,0 m

Содержание DZ RIO 350 JET FLEX

Страница 1: ...S LTDA Av Dr Labieno da Costa Machado 3526 Distrito Industrial CEP 17400 000 Gar a SP Brasil www ppa com br 0800 550 250 ATTENTION Do not operate the equip ment without first reading the instruction m...

Страница 2: ...y is compatible with that required on the equipment identification labe Do not connect the mains until installation maintenance is complete Always make electrical connections to the control unit with...

Страница 3: ...130 C Class B 130 C TRAVEL STOP Analogic Digital Analogic Digital Hybrid Maximum gate leaf mass 400 Kg 400 Kg 400 Kg MAXIMUN GATE DIMENSION HEIGHT 2 5 m LENGTH 3 0 m HEIGHT 2 5 m LENGTH 3 0 m HEIGHT...

Страница 4: ...REQUENCY 60 Hz 60 Hz 60 Hz NOMINAL POWER 450 W 395 W 140 W 170 W ENGINE RPM 1740 RPM 1740 RPM 4365 rpm NOMINAL CURRENT 2 1 A 3 1 A 1 1 A 1 7 A REDUCTION 1 23 1 23 1 23 LINEAR VELOCITY 17 1 m min Z18 1...

Страница 5: ...d closing properly Open the gate manually and observe the effort required This effort should be minimal for the entire length of the course Step 2 Close the gate manually and check whether the exertio...

Страница 6: ...on of this equipment depends on the instructions in this manual To fix the equipment proceed as follows Step 1 Make sure that the floor is firm enough so that the equipment can be screwed so that it i...

Страница 7: ...ll back the automation Step 6 With the automator unlocked position the rack bar on the gear and aligned with the gate It is necessary to leave approximately a clearance of 2 mm between the top of the...

Страница 8: ...ly attach the automation to the floor or concrete base tightening the bolts ANALOG END OF COURSE INSTALLATION Step 1 With the gate closed place the magnet holder in the rack positioned in front of the...

Страница 9: ...cessary invert the connector on the board After attaching the magnet holders make final adjustments by moving them to the right or left depending on the setting you want Step 4 To finalize the install...

Страница 10: ...Make sure that the power supply is connected correctly B Replace fuse with the same specification C Make sure that there is no object blocking the operation of the gate D Replace the end of course sys...

Отзывы: