PPA AGILITY PLUS Скачать руководство пользователя страница 26

26

SCREEN TO SELECT THE CONTROL BUTTON THAT WILL HAVE THE PANIC FUNCTION

Figure 20 - select transmitter button as panic

The panic button selected as “Access” means that all control keys that are recorded in the board, and that do 

not have any special function selected, but only access, will also be defined as a panic button, that is, Secure 

Access

1

.

U

I

N

P

T

C

A

T

N

O

B

K

x

:

x

e

x

y

x

s

x

x

PANIC FUNCTION KEY

Access

Содержание AGILITY PLUS

Страница 1: ...AGILITY PLUS BOARD PROGRAMMING GUIDE ALARM FUNCTION WARNING Do not use the equipment without first reading the instruction manual PXXXXX 05 2022 Rev 1...

Страница 2: ...4 Setting the time for triggering the panic alarm 30sec to 10min Enable Disable panic alarm silent mode WiFi only Siren only WiFi Siren Panic key action Pulse2 Only Secure Access1 Pulse Siren On Off a...

Страница 3: ...n be installed on the frame and on the gate for protection against break ins and tampering as a wireless sector Smart RF wireless infrared sensors can be installed to protect indoor area such as garag...

Страница 4: ...cessary that the gate is closed with the limit switch sensor activated by the gate magnet and also that the activated button of the transmitter is configured as Arm Trip After the board re cognizes an...

Страница 5: ...g as shown in the cycle shown below It starts at screen 1 and ends at screen 14 then returns to screen 1 repeating the cycle of display while the key is in use Figure 2 Cycle of alarm sectors and pani...

Страница 6: ...activities as follows Enabled Disabled Internal Arming Mode Time to arm timer Siren timer activated and PGM output triggered in hold mode Figure 3 Alarm on off screen and time for arming and siren Al...

Страница 7: ...the number of the detected sensor is indicated on the screen As an example in the image below the wired sector FCF and the wireless sectors 8 and 2 were detected by the board Figure 4 Test screen for...

Страница 8: ...mean that it is enabled and that it has not had any violations The sectors that have the indicator sign means that the sector has been violated The sectors that have the indicator sign means that the...

Страница 9: ...ut timer to trip or time to trip and Auto nullable counter Figure 6 Screen of conditions time to trigger and auto nullable counter of sectors If sector in internal arming mode then display letter i SD...

Страница 10: ...tton again by the user with the gate closed Figure 7 Panic Status Countdown clock for triggering panic alarm minutes seconds When only Key text is checked it means that the panic key event is register...

Страница 11: ...of 0 5 seconds a once The SN led board will start to flash in reverse mode that is turned on by 5 sec and off for 1 sec The alarm will be armed after automatic arming time is reached After arming the...

Страница 12: ...ed and there is a command to open the gate and after the closing of the closing cycle with the closing limit switch sensor activated by the magnet the alarm will be automatically reset and all sectors...

Страница 13: ...activated by the magnet press the button that was configured as internal arming to activate the monitoring of the sectors that are configured as internal arming The board will memorize the internal a...

Страница 14: ...he message Signal Sensor is displayed on the screen press the button to be registered in the board memory Displays number of recorded devices No signal Waiting for device signal Sector Sensor x Device...

Страница 15: ...then using the new device sending signal press the button for quick replacement After the operation is carried out it is displayed on the screen which sector the new device belongs to Using the butto...

Страница 16: ...Exclusion Screen Figure 13 To exclude all wireless devices from sectors press the button on the keyboard to perform the operation After operation the value 0 is displayed on the screen Displays numbe...

Страница 17: ...ure 14 Configuration screen of the time the siren will be on after the sector is violated and triggered button to increase the time value and button to decrease the time value S M N I E R T E I T x m...

Страница 18: ...igure 15 Time configuration screen when the board will arm the alarm for monitoring the sectors button to increase the time value and button to decrease the time value Automatic arm time Minimum 1 sec...

Страница 19: ...continuous pulsating state until the user programmed siren time expires The pulse time is 10 seconds on and 10 seconds off and then this process is repeated continuously until the siren time expires A...

Страница 20: ...sector is violated the PGM output will be turned on three consecutive times where for each activation it will be on for a period of 30 seconds and then it will be turned off for a period of 30 second...

Страница 21: ...llustrated in figure 17 the Agility Plus board ALARM function becomes a wireless sector with 9 sub sectors integrated for the alarm board like CODIGUS Otherwise the Agility Plus board ALARM function a...

Страница 22: ...PGM and LG outputs will be activated for a period of 0 5 seconds once signaling that the sectors that are activated will be monitored for protection When the gate is closed and the alarm is armed and...

Страница 23: ...ton set to arm disarm the PGM and LG outputs will be turned on once for a period of 0 5 seconds and the alarm will be armed after user defined arming time Disarmed alarm Arm time LG output PGM output...

Страница 24: ...ed Likewise when the gate ends the closing cycle and the alarm function is enabled the board will be armed after the user defined arming time time is reached In the two cases described above and after...

Страница 25: ...he panic alarm As the delay time for triggering the panic alarm must always be defined by the user longer than the time of the opening and closing cycle of the gate and after closing the cycle with th...

Страница 26: ...ton as panic The panic button selected as Access means that all control keys that are recorded in the board and that do not have any special function selected but only access will also be defined as a...

Страница 27: ...the user in the PROG settings Remembering that the time for panic triggering must be greater than the time of the complete cycle perfor med by the gate for opening and closing otherwise the panic alar...

Страница 28: ...alarm can be signaled by the Siren through the PGM module and also be sent to the PPA application via WiFi When the WiFi only device is selected to send the triggered panic alert signal to the PPA ap...

Страница 29: ...ecure Access Secure Access1 when pressing the key defined as panic 2 P Sir 3s Open Works only if the gate is closed If the key is pressed and released greater than 0 5sec and less than 3 0sec the sire...

Страница 30: ...he user again user with the gate closed or press the key of the PROG Countdown clock for triggering panic alarm minutes seconds When only the text Key is marked it means that the panic key event is re...

Страница 31: ...eters Wireless sectors sectors 1 to 8 are disabled by factory default Factory defaults Alarm Board TX ARM DISARM Button None TX INTERNAL ARM Button None SIREN TIME Time 3 minutes EXIT TIME AUTOMATIC A...

Страница 32: ...reen Figure 26 On this screen the sector that will be configured by the user is selected to have individual characteristics and behaviors as follows Enable Disable Trigger mode Nullable auto counter N...

Страница 33: ...as been violated the PGM output will be triggered instantly Trigger timer When an armed and sector alarm has been violated the PGM output will be activated after a user defined trip time Displays sele...

Страница 34: ...ty about the sector will be recognized In order to deactivate the auto lock a valid transmitter button command will be required to open the gate or a valid transmitter button command configured to arm...

Страница 35: ...the user Trigger by Sensor The countdown of the nullable counter will be carried out in the immediate triggering of the sensor in the sector This feature should be used as an example in cases where a...

Страница 36: ...in a monitoring state when the owner is inside the residence such as the gate the social door of the gate and the perimeter of the garage may be activated To activate this feature it will be necessar...

Страница 37: ...is case for correct operation all transmitter buttons must be recorded in the board as access and then define the individual characteristics of each button As an example in the figure below the ZAP4 t...

Страница 38: ...the buttons inverted in the hardware of the board then it will be necessary to carry out the test of the button first to know which button 1 button 2 button 3 and button 4 are with PROG Figure 33 Tran...

Страница 39: ...RIAN FUNCTION Setting button as pedestrian function Activate pedestrian function via PROG Figure 34 Screen to enable disable the pedestrian function T E N R D I E P A S x x x x x x x x x x x x PEDESTR...

Страница 40: ...S PEDESTRIAN FUNCTION Select which transmitter button will function as a pedestrian Figure 35 Screen to select the transmitter button for pedestrian function E I S P A T T E N X R D B O x U x N x T x...

Страница 41: ...41 HOW TO ACTIVATE THE ALARM FUNCTION Figure 36 Screen to enable disable the alarm function U R I A N M O L C N A T F x x x x x x x x x x x x ALARM FUNCTION Disabled Enabled...

Страница 42: ...m is disarmed and there is a command to open the gate and after closing the closing cycle with the closing limit switch sensor activated by the magnet the alarm will be automatically reset and all sec...

Страница 43: ...sensor activated by the magnet press the button that has been configured as internal arming to activate the monitoring of the sectors that are configured as internal arming The board will memorize the...

Отзывы: