11
ENABLING ALARM FUNCTION
Settings screens available in the PROG for parameterization of the functioning of the alarm function in the
Agility Plus board.
Figure 8 – Enable / Disable the alarm function
Able
Figure 8 - When the alarm board function is enabled and the gate is closed with the closing limit switch (FCF)
sensor activated, the garage light and the PGM output (TRV) will be activated for a time of 0.5 seconds a once.
The SN led board will start to flash in reverse mode, that is, turned on by 5 sec and off for 1 sec.
The alarm will be armed after automatic arming time is reached. After arming the board, the garage light and
the PGM output (PGM TRV MODE selected as Siren) will be activated again for a time of 0.5 seconds once.
Disabled
Figure 8 - When the alarm board function is disabled, the SN led will be off for 5 seconds and on for 1 second.
The garage light and PGM output (PGM TRV MODE selected as Siren) will be activated for a time of 0.5
seconds repeated twice.
ALARM FUNCTION
Disabled
Able