MAIN FEATURES OF THE ALARM FUNCTION
• 1 Wired Sector [Closing limit switch – FCF]
• 8 Wireless Sectors 433.92MHz [ Magnetto / Smart RF ]
• Selection of ZAP4 transmitter button as Arm / Disarm function
• Selection of ZAP4 transmitter button as Internal Arming function
• Replacement or exchange of the defective sector’s wireless device without the need to delete and re-record
all sectors.
• Siren time [1 minute to 240 minutes]
• Auto-arm exit time [1 second to 240 seconds]
• Latch output as PGM module programmable output [ Siren, Hold, Pulsed, 1 Pulse, 2 Pulses, 3 Pulses and
Remote control wrist ]
• Individual programming for each sector:
- Sector ON / OFF
- Shooting Mode (Instant or Timed [1 second up to 240 seconds])
- Auto-Cancellable Counter (OFF, Number of Events [1 to 250])
- Auto Override Mode (Siren Trigger or Sensor Trigger)
- Internal Arming (ON, OFF)
• Enable / Disable armed warning beep silent mode when gate is closed, as follows:
- Garage Light Only
- Garage Light + Siren
- Siren only
• Configurable Panic Button Function:
- Enable / Disable
- Selection of the panic button on the control
- Access buttons
- Button #1, Button #2, Button #3 or Button #4
- Setting the time for triggering the panic alarm [30sec to 10min]
- Enable / Disable panic alarm silent mode
- WiFi only
- Siren only
- WiFi + Siren
- Panic key action
- Pulse
2
=Only Secure Access
1
- Pulse=Siren On/Off and Time 3seg=Secure Access
- Pulse=Secure Access and Time 3sec
3
= Siren On/Off
- Monitoring and Resetting of panic functions.
• Communication interface with the Contatto Wi-Fi Connect device
• Schedules performed by PROG
• Verification of the operating conditions of the alarm, sectors and panic through the PROG display
Notes:
1
When the gate is closed and the board receives a signal from the control where the button has a panic function, it will simultaneously trigger the panic timer and trigger
the gate to open, starting the Safe Access cycle. It is important to remember that the user-defined panic delay time value must be greater than the time to complete the gate
opening/closing cycle, otherwise it will trigger the panic signal before completing the gate closing cycle.
2
The board recognizes and treats the control’s panic button as Pulse when this button is pressed and released from the control between the times of 0.5sec and 3sec.
3
The board recognizes and treats the control’s panic button as Tempo 3sec when this button is pressed and held on the control above the 3sec time.