Chapter 5 Function parameter
43
Ch
ap
ter 5
under keyboard operation mode
1:STOP/RES key is enabled under
any operation mode
186 F6.01
Running status display
parameters 1
0x0000 to 0xFFFF
001F
☆
187 F6.02
Running status display
parameters 2
0x0000 to 0xFFFF
0000
☆
188 F6.03 Stop status display parameters
0x0000 to 0xFFFF
0033
☆
189 F6.04 Load speed display coefficient
0.0001 to 6.5000
3.0000
☆
190 F6.05
Decimal places for load speed
display
0:0 decimal places
2:2 decimal places
1:1 decimal places
3:3 decimal places
1
☆
191 F6.06
Inverter module radiator
temperature
0.0
℃
to 100.0
℃
-
●
192 F6.07 Total run time
0h to 65535h
-
●
193 F6.08 Total power-on time
0h to 65535h
-
●
194 F6.09 Total power consumption
0 to 65535 kwh
-
●
195 F6.10 Product series number
Frequency inverter series number
-
●
196 F6.11 Software version number
Control board software version
-
●
197 F6.13
Communication read-write data
selection
Bit: CRC error response selection
0:CRC error response selection;
1:CRC error response selection
Ten: broadcast message screening
option
0: no shielding; 1: shielding.
100 bits: frequency converter fault
information read selection
0: read; 1: not read.
011
☆
198 F6.16 Monitor selection 2
1Kbit/100bit 10bit/1bit
d0.04
☆
parameter
number
parameter series
number
199 F6.17 Power correction coefficient
0.00
~
10.00
1.00
☆
200 F6.18 Multifunction key definition 1
0: UP key is defined as add
function key
1: UP key is defined free stop
2: UP key is defined Forward
running
3: UP key is defined Reverse
running
4: UP key is defined Forward Jog
running
5: UP key is defined Reverse Jog
running
6: UP key is defined UP function
key
7: UP key is defined DOWN
function key
0
☆