Vision Maxi

 User Instructions  Doc Ref M609 issue 1.0 June 2021.

Содержание Vision Maxi

Страница 1: ...w w w p o w r m a t i c c o u k Doc Ref M609 Issue 1 0 June 2021 Vision Maxi Installation Servicing Manual Issue 1 0 June 2021...

Страница 2: ...our behalf Conditions of Guarantee 1 The air conditioner must have been installed by a competent installer and in accordance with the manufacturer s instructions and any building regulations and local...

Страница 3: ...tive and implementing regulation 206 2012 EU and Italian implementing regulation Legislative Decree no 15 of 16 02 2011 F Gas Regulation 2014 517 EU on fluorinated greenhouse gases And subsequent amen...

Страница 4: ...4 2 6 Unpacking p 14 2 7 Handling without packaging p 15 2 8 Installation site p 15 2 9 Installation minimum distances p 16 2 10 Positioning p 16 2 11 Condensation drain preparation p 20 2 12 Electric...

Страница 5: ...age no 5 of 36 Vision Maxi User Instructions Doc Ref M609 issue 1 0 June 2021 5 Technical information p 32 5 1 Technical data p 32 5 2 Dimensions p 33 5 3 RED Compliance Statement p 33 5 4 Safety p 33...

Страница 6: ...ammable and odourless Avoid proximity to sources of ignition in continuous operation open flames gas appliances electric stoves lighted cigarettes etc Instructions Read the instructions carefully befo...

Страница 7: ...re is pressurised refrigerant gas and live electrical components inside the appliances The installation and subsequent maintenance phases must be carried out exclusively by authorised and qualified pe...

Страница 8: ...to off It is forbidden to modify the safety or adjustment devices or adjust without authorization and indications of the manufacturer It is forbidden to pull unplug or twist the device s electric cabl...

Страница 9: ...efore invalidates the warranty 1 8 Destination of use These appliances have been designed for conditioning and or heating rooms and they must be destined solely for this purpose in accordance with the...

Страница 10: ...i lifting bracket 11 External air expulsion 12 Remote control 13 Internal exchanger 14 External fan 15 Condensation pump 16 Condensation drain valve 17 Floater 18 External exchanger 19 External air pr...

Страница 11: ...L00771II Recessed formwork for corner installation with left hand exit Compatible with only DC Inverter versions All L00772II Accessories supplied separately Grilles and accessories Kit n 2 external...

Страница 12: ...ut to ensure that the risk of combustion is minimised before starting work on systems containing flammable refrigerants The appliance must be protected against accidental impacts to prevent mechanical...

Страница 13: ...when the load is lifted off the ground Avoid dangerous situations when using a hoist to lift the appliance During transportation the appliance must be kept in vertical position Avoid exposure to sour...

Страница 14: ...e The equipment must always be handled vertically Check if there is refrigerant inside the package using an electronic leak detector suitable for the system refrigerant If it is present the refrigerat...

Страница 15: ...ecessary to check carefully that the weight of the unit does not exceed the regulations in relation to the number of people used 2 8 Installation site The location of the appliance must be determined...

Страница 16: ...use damage to persons or property if it should detach from its base The unit should not be installed in a position where the air flow is aimed directly at the people nearby Provide the following a nea...

Страница 17: ...or models 15 HP DC Inverter B C F IN OUT D E A Hold the template in the correct position with tape Preliminary warnings The wall mounting bracket supplied as an accessory is required to position the u...

Страница 18: ...xternal side The maximum length of the holes is 1 meter Curves are prohibited To prevent the creation of large quantities of dust and debris in the room it is recommended to couple the core drill to a...

Страница 19: ...r so that the flaps are in vertical position insert the counterflange in the hole toward the interior of the room rotate it so that the hooks are in vertical position pull the chains so that the sprin...

Страница 20: ...If the line flows into a container e g a tank do not close the container hermetically and avoid immersing the draining pipe into the water The hole for the condensation pipe must always slope towards...

Страница 21: ...eakage of water The drainage pipe must be insulated for sections running inside houses in order to prevent condensate formation on its surface If needed it is possible to empty the condensation collec...

Страница 22: ...e of minimum 3 mm or using a device enabling the complete disconnection of the appliance in overvoltage III category conditions Please check that the power supply is provided with suitable protections...

Страница 23: ...apter Removal of aesthetic panels and grilles p 27 To access the connections unscrew the screws of the electrical panel remove the electrical panel cover Connection The appliance leaves the factory fu...

Страница 24: ...the CP contact that places the device in standby and guarantees correct post ventilation GR Grey BR Brown YG Yellow Green BL Blue CP Presence contact G R G R C P G R BL YG BR Configuration with the ne...

Страница 25: ...esthetic lower cover kit Code GB0737II 2 Fixing screws supplied with the optional kit GB0737II 3 Right support bracket for the flap A B 1 3 2 180 Configuration After adjusting the air outlet flap posi...

Страница 26: ...y for 3 seconds The lock remains active also for the next operations performed via remote control and in the event of a power failure 2 17 hotel function Keep the key pressed for 10 seconds If the En...

Страница 27: ...9 issue 1 0 June 2021 2 19 Removal of aesthetic panels and grilles 2 1 2 20 Assembly of aesthetic panels and grilles To assemble positioning the aesthetic panel insert the two screws Screw in the two...

Страница 28: ...nces electric stoves lighted cigarettes etc Smoking in the vicinity of the appliance is prohibited Using a mobile phone near the appliance is prohibited Using leak detectors with halogen lamps is proh...

Страница 29: ...c panels and grilles p 27 For grid assembly operations see chapter Assembly of aesthetic panels and grilles p 27 extract the filter by lifting it remove the dust from the filter with a vacuum cleaner...

Страница 30: ...m irons hot plates etc Displayed faults In the event of a malfunction the display shows an alarm code The appliance still retains some functions see the OPERATION column Alarm Cause Function E1 Faulty...

Страница 31: ...rvice During heating condensation should drain freely through the specific pipe In the event of an alarm check that the condensation pipe is not bent or obstructed thus preventing the water from flowi...

Страница 32: ...minimum fan speed m h 300 Aeraulic data outdoor Ventilation speed Nr 3 Air flow at the maximum fan speed m h 550 Air flow at the medium fan speed m h 460 Air flow at the minimum fan speed m h 400 Ele...

Страница 33: ...ight mm 549 Total depth mm 165 Empty weight kg 41 0 Wall hole diameter mm 202 Wall holes distance mm 293 5 3 RED Compliance Statement Compliancewith2014 53 EURadioEquipmentDirective RED In accordance...

Страница 34: ...page no 34 of 36 Vision Maxi User Instructions Doc Ref M609 issue 1 0 June 2021 Notes...

Страница 35: ...page no 35 of 36 Vision Maxi User Instructions Doc Ref M609 issue 1 0 June 2021 Notes...

Страница 36: ...e mail info powrmatic ie web www powrmatic ie Getting In Touch Powrmatic pursues a policy of continues improvement in both design and performance of its products and therefore reserves the right to c...