9
• Washing, brushing, drying cycle
Press button 2 to start the vacuum, button 4 (Fig 9) to
release solution and press the lever 5 (Fig 10) to start
the cycle.
4.3 Using the machine
WARNING!
Never start the machine without a
brush or pad attached.
• Set the handle at a comfortable working height.
• Start the machine and select the type of cycle. Start the
cleaning operation by pressing the levers and holding
them pressed to start rotation of the brush or pad and
to dispense cleaning solution, then push the machine
in a forward direction using handles on the handle bar.
• Releasing the lever stops the rotation of the brush and
the dispensing of solution.
WARNING
– to avoid damaging the floor DO NOT
use the machine in a fixed position with the brush
rotation activated. The machine must be moving
while the brush is rotating.
• IMPORTANT
– the correct way of cleaning and drying
the floor is to move the machine forward. Moving the
machine backwards damages the blades and does not
allow water to be vacuumed from the floor.
• If necessary, adjust the volume of solution using the
tap (See pic 15 & 16).
Fig 15 Solution tap fully closed
Fig 16 Solution tap fully opened
• Check the status of the battery charge by the indicator
(pic).
• Proceed to operate the machine in the normal manner,
releasing cleaning solution from time to time as
required.
• For heavy soil, scrub floor with cleaning solution but
with vacuum motor OFF. Scrub floor again, picking up
the solution.
• WARNING
- If foam or liquid is leaking, turn machine
off immediately and empty recovery tank. Leaking
liquid could be hazardous due to its temperature, or
chemical content.
• To STOP the machine, release solution feed levers,
switch off brush motor then vacuum motor.
IMPORTANT! If it is necessary to replace the
brush or pad during cleaning please follow
instructions in section 2.4.
5. Warnings while using the machine
• While using the machine, errors are indicated by
flashing and lit LEDs
• LED 1 is flashing and LED 2 is constantly lit – Suction
unit outlet over current.
• LED 1 is flashing and LED 3 is constantly lit – Brush
unit outlet over current.
• LED 1 is flashing and LED 4 is constantly lit – Suction
unit outlet open circuit.
• LED 1 is flashing and LED 5 is constantly lit – Brush
unit outlet open circuit.
Fig 17
NOTE:
When any of the above mentioned error signals
are displayed, it is necessary to turn off the machine and
then turn the machine back on again in order to clear the
error and re-set the machine back to normal functioning.
5.1 When cleaning is finished
• Before turning off the machine, stop the dispensing of
solution and the rotation of brushes by releasing levers.
Continue with the vacuum ON to remove all of the
liquid present on the floor. Then turn off the vacuum by
pressing button 2. (Fig 9)
• Raise the squeegee by pulling the squeegee lifting
lever and releasing it. The lever remains in an upper
position keeping the squeegee blades in the raised
position.
WARNING
– always lift up the squeegee at the end of
the cleaning in order to prevent the deformation of the
rubber blades.
• Remove brush or pad from machine and wash in warm
soapy water.
5
4
2
3
1