Powr-Flite PAS14G Скачать руководство пользователя страница 9

9

•  Washing, brushing, drying cycle

   Press button 2 to start the vacuum, button 4 (Fig 9) to 

release solution and press the lever 5 (Fig 10) to start 

the cycle.

4.3 Using the machine

WARNING!

 Never start the machine without a 

brush or pad attached.

•  Set the handle at a comfortable working height.

•  Start the machine and select the type of cycle. Start the 

cleaning operation by pressing the levers and holding 

them pressed to start rotation of the brush or pad and 

to dispense cleaning solution, then push the machine 

in a forward direction using handles on the handle bar.

•  Releasing the lever stops the rotation of the brush and 

the dispensing of solution.

WARNING

 – to avoid damaging the floor DO NOT 

use the machine in a fixed position with the brush 

rotation activated. The machine must be moving 

while the brush is rotating.

• IMPORTANT

 – the correct way of cleaning and drying 

the floor is to move the machine forward.  Moving the 

machine backwards damages the blades and does not 

allow water to be vacuumed from the floor.

•  If necessary, adjust the volume of solution using the 

tap (See pic 15 & 16).

 

Fig 15 Solution tap fully closed

 

Fig 16 Solution tap fully opened

•  Check the status of the battery charge by the indicator 

(pic).

•  Proceed to operate the machine in the normal manner, 

releasing cleaning solution from time to time as 

required.

•  For heavy soil, scrub floor with cleaning solution but 

with vacuum motor OFF. Scrub floor again, picking up 

the solution.

• WARNING

 - If foam or liquid is leaking, turn machine 

off immediately and empty recovery tank. Leaking 

liquid could be hazardous due to its temperature, or 

chemical content.

•  To STOP the machine, release solution feed levers, 

switch off brush motor then vacuum motor.

IMPORTANT! If it is necessary to replace the 

brush or pad during cleaning please follow 

instructions in section 2.4.

5. Warnings while using the machine

•  While using the machine, errors are indicated by 

flashing and lit LEDs

•   LED 1 is flashing and LED 2 is constantly lit – Suction   

  unit outlet over current.

•   LED 1 is flashing and LED 3 is constantly lit – Brush    

  unit outlet over current.

•   LED 1 is flashing and LED 4 is constantly lit – Suction   

  unit outlet open circuit.

•   LED 1 is flashing and LED 5 is constantly lit – Brush    

  unit outlet open circuit.

Fig 17

NOTE:

 When any of the above mentioned error signals 

are displayed, it is necessary to turn off the machine and 

then turn the machine back on again in order to clear the 

error and re-set the machine back to normal functioning.

5.1 When cleaning is finished

•  Before turning off the machine, stop the dispensing of 

solution and the rotation of brushes by releasing levers.  

Continue with the vacuum ON to remove all of the 

liquid present on the floor. Then turn off the vacuum by 

pressing button 2. (Fig 9)

•  Raise the squeegee by pulling the squeegee lifting 

lever and releasing it.  The lever remains in an upper 

position keeping the squeegee blades in the raised 

position.

WARNING

 – always lift up the squeegee at the end of 

the cleaning in order to prevent the deformation of the 

rubber blades.

•  Remove brush or pad from machine and wash in warm 

soapy water.

5
4

2

3

1

Содержание PAS14G

Страница 1: ...MANUAL WARNING OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT Tacony Corporation All rights reserved Save These Instructions Automatic Scrubber PAS14G PAS14G...

Страница 2: ...n tank 7 3 Controls 7 4 Operation 8 4 1 Checks before use 8 4 2 Preparing the machine and choosing the cycle 8 4 3 Using the machine 9 5 Warnings while using the machine 9 5 1 When cleaning is finishe...

Страница 3: ...Recovery tank 7 Recovery tank lid 8 Solution tank 9 Solution tank filling opening 10 Wheels 11 Brush guard 12 Brush 13 Squeegee 14 Recovery tank drain hose 15 Vacuum hose 16 Battery charger lead 17 Ba...

Страница 4: ...d in any way Contact an authorized service agent for repair or adjustment Do not operate switches or touch the power cord plug with wet hands as this may cause electric shock When unplugging pull on t...

Страница 5: ...may impair the safety of the machine and void the warranty WARNING The machine must be switched off before adding or changing accessories 1 5 Transporting the machine CAUTION THIS MACHINE IS HEAVY Do...

Страница 6: ...are required for complete battery charge IMPORTANT Overcharging will damage the batteries This will cause run time to be reduced and overall bat tery life will be affected AVOID OVER CHARGING 2 3 Adj...

Страница 7: ...y is 4 5 gal Do not overfill the tank as spills may occur when in use IMPORTANT When the solution tank has emptied switch off the machine and empty the recovery tank before refilling the solution tank...

Страница 8: ...Fig 12 on the squeegee is not blocked and that the hose is connected correctly Fig 12 Check the status of the battery charge by pressing brush switch 3 Fig 9 Check that the water filter is clean and f...

Страница 9: ...foam or liquid is leaking turn machine off immediately and empty recovery tank Leaking liquid could be hazardous due to its temperature or chemical content To STOP the machine release solution feed l...

Страница 10: ...clean the solution tank to prevent deposits or scaling Position the machine over a drain outlet Turn the drain connector outwards Fig 19 Fig 19 Push the hose clip 1 inwards while removing the cap lett...

Страница 11: ...ularly inspect sheath and plug for damage or loose connections Replace the supply cord only with the type specified in these instructions Recovery tank Check condition and clean tank Squeegee blades C...

Страница 12: ...it sharply CCW onto the clutch Make sure the lugs on the clutch plate fully engage the brush pad driver Fig 24 7 4 Replacing the fuses Fig 25 WARNING Replace the blown fuse with one with the same ampe...

Страница 13: ...service Repairs and servicing of Powr Flite products should only be performed by trained staff Improper repairs can cause considerable dangers to the user 9 Guarantee Your product is guaranteed for o...

Страница 14: ...speed rpm 130 Theoretical hourly working capacity ft hour 10 300 Solution tank capacity gal 4 5 Recovery tank capacity gal 6 8 Brush motor rating W 260 Vacuum motor rating W 250 Air flow CFM 59 Vacuu...

Страница 15: ...t outlet over current error or vacuum unit circuit error Vacuum button not pressed on handle controls See paragraph Warning signals while using the machine Section 5 Press the button The machine does...

Страница 16: ...th written manuals or other instructions for a period of 1 year from date of purchase on workmanship motor and parts In case you as our customer meet any trouble with your machine contact a Powr Flite...

Отзывы: