11
• When storing the machine for long periods, remove the
brush and put the squeegee in the up position.
• Store the machine in a dry indoor area only.
6.1 Prolonged machine standstill
• Drain any water contained in the tanks.
• Place the machine under cover, sheltered from
atmospheric agents in a place where the temperature
is between 40°F and 105°F.
• Charge the batteries and, once they are charged,
disconnect them from the charger. Refer back to
section 2.1 and follow in reverse order.
• Charge the batteries once a month.
7. Maintenance
WARNING - Before making adjustments
or performing maintenance, switch off the
machine, unplug from the power supply and
disconnect the non-grounded pole of the
battery.
• Do not rest tools and metal objects on the batteries;
danger of short circuits.
• Do not use harsh detergents, acid, lye etc. during
cleaning and washing. Take particular care with
electrical parts.
• Do not wash the machine with direct or pressurized
jets of water.
• When the machine must be lifted for any maintenance
operations, it is necessary to work safely by placing
fixed supports underneath it.
• Contact an authorized support center for repairs and
request ORIGINAL spare parts only.
The machine requires minimal maintenance apart from
the following checks by a trained operator.
• Battery charge cord
- Regularly inspect sheath
and plug for damage or loose connections. Replace
the supply cord only with the type specified in these
instructions.
• Recovery tank
– Check condition and clean tank
• Squeegee blades
– Check condition and replace
worn or damaged blades.
7.1 Replacing the squeegee rubber blades
(Fig 22).
When it becomes clear that drying the floor is difficult
or traces of water remain on the floor, it is necessary to
check the wear on the squeegee rubber blades (3):
• Remove the squeegee unit (1) as indicated in the
“Cleaning the squeegee” section 5.4.
• Loosen the finned nuts (2) and remove the rubber
blades (3).
NOTE:
When the rubber blades (3) are worn on one
side, they may be turned over one time.
• Replace or turn over the rubber blades (3) without
inverting them.
• Replace all the components in reverse order.
Fig 22
NOTE:
It is possible to have two types of rubber blades. Para
rubber blades for all types of floors and polyurethane
rubber blades for mechanical workshop floors which are
dirty with oil.
7.2 Squeegee set up (correct position)
(Fig. 23)
• Lower the squeegee using the squeegee lever.
• Start the vacuum and move forward several feet
before stopping the suction unit and the machine.
• Check the angle of the rubber blades (1) on the floor.
Fig. A = too low
Fig. B = too high
Fig. C = correct position
• Remove the squeegee unit from the machine
• To reposition the blade, loosen the screw (2) of the
wheel (3) and move the wheel vertically in the slot
lifting or lowering the wheel, to achieve the correct
position (C).
Fig 23