![Powerwerx DB-750X Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/powerwerx/db-750x/db-750x_user-manual_1592181022.webp)
17
7
General Setting
In VFO mode, when this function is on, the scanning or input of
frequency will be restricted within the current VFO frequency band.
1.
Press
key to enter function menu.
2.
Turn the main band selector knob to
choose No. 04 menu. The LCD displays "
BANd
"
3.
Press the main band selector knob to enter function setup.
4.
Switch the main band selector knob to choose desired value.
ON:
Turn on VFO band lockout function
OFF:
Turn off VFO band lockout function
5.
Press the main band selector knob or
key to store value and
return to function menu. Press
key or hold selector knob for 1
second to store setup and exit.
1.
Press
key to enter function menu.
2.
Turn the main band selector knob to
choose No. 05 menu. The LCD displays "
BEEP
"
3.
Press the main band selector knob to enter function setup.
4.
Switch the main band selector knob to choose wanted value.
ON:
Turn on Beep function.
OFF:
Turn off Beep function
5.
Press the main band selector knob or
key to store value and
return to function menu. Press
key or hold selector knob for
one second to store setup and exit.
When any harmonic or image frequency in the CPU clock disturbs the
working frequency, turn on this function to cut the image channel noise.
1.
Press
key to enter function menu.
2.
Turn the main band selector knob to
choose No. 06 menu. The LCD displays "
CLK.SFT
"
3.
Press the main band selector knob to enter function setup.
4.
Switch the main band selector knob to
choose desired value.
ON:
Turn on CPU clock frequency change
OFF:
Turn off CPU clock frequency change
5.
Press the main band selector knob or
key to store value and
return to function menu. Press
key or hold selector knob for one
second to store setup and exit.
1.
Press
key to enter function menu.
2.
Turn the main band selector knob to
choose No. 07 menu. The LCD displays "
2TN ENC
"
3.
Press the main band selector knob to enter function setup.
4.
Switch the main band selector knob to
choose desired value.
Available Values:
0-23
, total 24 groups.
VFo BAnD lockoUT
BEEp FUncTion
cpU clock FREqUEncY chAnGE
2 TonE EncoDE SElEcT
This function is auto-hidden in channel mode
if 2-Tone encode is programmed with name, the LCD will display
corresponding name.
After choosing the 2-Tone encode group, pressing PTT will transmit
selected code.
5.
Press the main band selector knob or
key to store value and
back to function menu. Press
key or hold selector knob for 1
second to store setup and exit.
NOTE
NOTE
NOTE