powersoft_dcell504_uguide_en_v4.0
www.powersoft-audio.com
14
D-Cell504
User Guide
Wiring Configurations & Operation Modes
D-Cell’s output stage is designed to work in balanced supply mode: this allows better exploitation of power supply capacitors
and power supply dynamic.
The physical signal path, as shown in Figure 4.1, lead to have CH1 in inverting operation respect to CH2.
In particular, CH1 output is inverting, while CH2 is non-inverting.
The first inversion is operated, on both channels, inside the DSP: this means that in the
D-Cell504
basic version, without the
DSP, we have the opposite situation, with CH1 non-inverting output and CH2 inverting output.
For proper connection please read carefully the following connecting instructions.
The inverting channel’s output connector hot pole is the negative and the positive of the output is grounded:
do not to reverse output signal of inverting channel to maintain grounded negative output.
Damage of the unit may occur in case of equally phased outputs.
VERSIONS WITHOUT DSP
VERSIONS WITH DSP
Содержание D-Cell504 IS