SECTION 3 – FEATURES
Protections
1) Clip
limiter:
Acts as input stage gain reduction since Input/Output comparation detects differences exceeding 1% THD.
Time constants are defined for +3dB input drive respect to input sensitivity:
Attack time = 5mS ; Hold time =10mS ; Decay time = 70mS
2) Average Power Limiter:
Acts as input gain reduction to reach a stationary output power of 120W independently to load conditions.
Integration constant delay Time=
4 sec.
3) Average High Frequency Limiter:
Acts as input gain reduction to reach a stationary output voltage of -K*(dB) respect to full output swing for
frequencies above 7 KHz
4) Average Current Protection:
Acts as amplification stage shutdown (mute) when average output current of 7.5 A
rms
is measured.
5) Peak Current Shut Down:
Acts as output stage switching process inhibition.
Self resetting after 2 Seconds.
Tripping point= 35 A
6) Temperature
Protection:
Acts reducing the output stage gain above temperature level of 85°C (temperature on output power devices
proximity).
T plate <80°C= TEMPOUT not active
T plate
≥
80°C= TEMPOUT active (turns on/off and the led blinks
slowly
)
T plate
≥
85°C= TEMPOUT active (turns on/off and the led blinks
fast
)
T plate
≥
90°C= Output Shutdown; TEMPOUT steady on
Temperature
Detector
VCA
input
Output
Stage
output
Peak Current Detector
Average Power Detector
Average Hi-Freq. Detector
Average Current Detector
Input-Output Comparator