8. Specifications 

 

CAPACITY* 

6000 VA / 4800 W 

10000 VA / 8000 W 

INPUT 

Low Line Loss 

110 VAC ± 3 % at 50% Load; 176 VAC ± 3 % at 100% Load 

Low Line Comeback 

Low Line Loss V 10V 

High Line Loss 

  300 VAC ± 3 % 

Voltage 
Range 

High Line Comeback 

High Line Loss Voltage - 10V   

Frequency Range 

46Hz ~ 54 Hz @ 50Hz system; 56Hz ~ 64 Hz @ 60Hz system 

Phase 

Single phase with ground 

Power Factor 

 0.99 at 100% Load 

OUTPUT 

Output voltage 

208/220/230/240VAC 

AC Voltage Regulation   

± 1% 

Frequency Range   

(Synchronized Range) 

46Hz ~ 54 Hz @ 50Hz system 

56Hz ~ 64 Hz @ 60Hz system 

Frequency Range (Batt. Mode) 

50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz 

AC mode 

100%~110%: 10min, 110%~130%: 1min, >130% : 1sec 

Overload 

Battery mode 

100%~110%: 30sec, 110%~130%: 10sec, >130% : 1sec 

Current Crest Ratio 

3:1 max 

Harmonic Distortion 

 3 % @ 100% Linear Load; 

 6 % @ 100% Non-linear Load 

Line

Battery 0 

ms 

Inverter

Bypass 0 

ms 

Transfer 

Time 

Inverter

ECO <10 

ms 

EFFICIENCY 

AC mode 

> 89% 

Battery Mode 

> 88% 

BATTERY 

Type & Numbers 

12 V / 7 Ah x 20 

12 V / 9 Ah x 20 

Recharge Time 

3 hours recover to 90% capacity 

4 hours recover to 90% capacity   

Charging Current   

2.0 A ± 10% (max.) 

Standard 

Model 

Charging Voltage   

14.4 V ± 1%   

Type 

Depending on applications 

Numbers 18 

20 

Charging Current   

2.0 A ± 10% (max.) 

Long-run 

Model 

Charging Voltage 

14.4 V ± 1%   

PHYSICAL 

Dimension, D X W X H 

UPS unit: 580 X 438 X 133 

Battery bank: 580 X 438 X 133 

UPS unit: 668 X 438 X 133 

Battery bank: 580 X 438 X 133 

Standard 

Model 

Net Weight (kgs) 

UPS unit: 17 

Battery bank: 57 

UPS unit: 20 

Battery bank: 63 

Dimension, D X W X H 

580 X 438 X 133 

668 X 438 X 133 

Long-run 

Model 

Net Weight (kgs) 

17 

20 

ENVIRONMENT

 

Operation Temperature 

0 ~ 40°C (the battery life will down when > 25°C) 

Operation Humidity 

<95 % and non-condensing 

Operation Altitude** 

<1000m 

Acoustic Noise Level 

Less than 55dB @ 1 Meter 

Less than 58dB @ 1 Meter 

MANAGEMENT 

Smart RS-232 or USB 

Supports Windows® 98/2000/2003/XP/Vista/2008, Windows® 7, Linux, 

and MAC 

Optional SNMP 

Power management from SNMP manager and web browser 

* Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC. 
**If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m. 
***Product specifications are subject to change without further notice. 

Содержание Centurion PSCER10000

Страница 1: ...Centurion 6000 10000 VA Rack Online UPS Users Manual www powershield com au...

Страница 2: ...distortions The Centurions true online double conversion topology will continuously protect your equipment by internally isolating your equipment from the utility power ensuring that all your equipme...

Страница 3: ...ngs and operating instructions in this manual strictly Save this manual properly and read carefully the following instructions before installing the unit Do not operate this unit before reading throug...

Страница 4: ...TION 7 2 4 UPS INSTALLATION FOR PARALLEL SYSTEM 8 2 5 SOFTWARE INSTALLATION 8 3 OPERATIONS 9 3 1 BUTTON OPERATION 9 3 2 LED INDICATORS AND LCD PANEL 9 3 3 AUDIBLE ALARM 11 3 4 UPS OPERATION 12 3 5 ABB...

Страница 5: ...Do not connect appliances or devices which would overload the UPS e g big motor type equipment to the UPS output sockets or terminal Place cables in such a way that no one can step on or trip over th...

Страница 6: ...onnect the mains Ensure that no liquid or other foreign objects can enter into the UPS system The UPS can be operated by any individuals with no previous experience 1 5 Standards Safety IEC EN 62040 1...

Страница 7: ...One PowerShield NetGuard UPS monitoring software CD One RS 232 cable One USB cable One EPO plug Fitted on the rear panel NOTE Before installation please inspect the unit Be sure that nothing inside t...

Страница 8: ...nput power source for the UPS as its rated current is less than the UPS s maximum input current Otherwise the receptacle may be burned and destroyed 2 Switch off the mains switch in the building befor...

Страница 9: ...re installation NOTE Set the battery pack breaker in OFF position and then install the battery pack Pay attention to the rated battery voltage marked on the rear panel If you want to change the number...

Страница 10: ...CVCF mode UP key Press this button to display next selection in setting menu Mute Down Button Mute the alarm Press and hold the button more than 0 5s to mute the buzzer Please refer to section 3 4 9...

Страница 11: ...cates that the UPS alarm is disabled Output Battery voltage information Indicates the output voltage frequency or battery voltage Vac output voltage Vdc battery voltage Hz frequency Load information I...

Страница 12: ...ce every 2 minutes Battery mode Beeping once every 4 seconds Fault mode Beeping continuously Yes Warning Overload Beeping twice every second Low battery Battery unconnected Over charge EPO enable Fan...

Страница 13: ...e UPS is turned on you can connect devices to the UPS 1 Turn on the UPS first and then switch on the devices one by one the LCD panel will display total load level 2 If it is necessary to connect the...

Страница 14: ...when the UPS is running in AC mode CVCF mode ECO mode you could press the Test button to let the UPS do battery self test 2 To keep the system reliable the UPS will perform the battery self test auto...

Страница 15: ...battery and output immediately to avoid more risk or danger 12 Operation of changing battery numbers 1 This operation is only available for professional or qualified technicians 2 Turn off the UPS If...

Страница 16: ...t 01 Output voltage Y 02 Output frequency Y 03 Voltage range for bypass Y 04 Frequency range for bypass Y 05 ECO mode enable disable Y 06 Voltage range for ECO mode Y 07 ECO mode frequency range setti...

Страница 17: ...ting in parameter 2 The input frequency could be from 46Hz to 64Hz NCF Setting UPS to normal mode not CVCF mode If selected the output frequency will synchronize with the input frequency within 46 54...

Страница 18: ...Parameter 3 Set high voltage point for ECO mode 50 Hz Setting range is from 52 0Hz to 54 0 Hz 60 Hz Setting range is from 62 0Hz to 64 0Hz The default value is 52 0Hz 62 0Hz z 08 Bypass mode setting...

Страница 19: ...programmable output Interface Setting These functions are not supported by the Rack model z 12 Reserved Interface Setting Reserve for future options z 13 Battery voltage adjustment Interface Setting...

Страница 20: ...ttery specifications z 15 Output voltage adjustment Interface Setting Parameter 2 you may choose Add or Sub to adjust inverter voltage Parameter 3 the voltage range is from 0V to 6 4V the default valu...

Страница 21: ...de LCD display Description When input voltage is within acceptable range and bypass is enabled turn off the UPS and it will enter Bypass mode Alarm beeps every two minutes Bypass mode LCD display Desc...

Страница 22: ...start failure 11 None Over temperature 41 None High Inverter voltage 12 None CPU communication failure 42 None Low Inverter voltage 13 None Overload 43 Inverter output short circuited 14 3 9 Warning I...

Страница 23: ...is locked in the Bypass mode Connected devices are fed directly by the mains Remove excess loads from UPS output first Then shut down the UPS and restart it Fault code is shown as 43 The icon lights o...

Страница 24: ...most common problem 3 If the problem still persists please call 1300 305 393 for technical support or fill in the form in PowerShield web page for on line technical support Following details are need...

Страница 25: ...nd with the required precautionary measures may replace batteries and supervise operations Unauthorized persons must be kept well away from the batteries Verify that no voltage between the battery ter...

Страница 26: ...recover to 90 capacity Charging Current 2 0 A 10 max Standard Model Charging Voltage 14 4 V 1 Type Depending on applications Numbers 18 20 Charging Current 2 0 A 10 max Long run Model Charging Voltage...

Страница 27: ...37 100350 00G...

Отзывы: