Owner’s Manual for Portable Generator
7
Hour Meter
The Hour Meter tracks hours of operation for
scheduled maintenance. See
• The CHG OIL display will illuminate every
100 hours. The message will flash one hour
before and one hour after each 100 hour
interval, providing a two hour window to
perform service.
• The SVC display will illuminate every 100
hours. The message will flash one hour
before and one hour after each 200 hour
interval providing a two hour window to per
-
form service.
When the hour meter is in flash alert mode,
the maintenance message will alternate with
elapsed time in hours and tenths. The hours
will flash four times, then alternate with the
maintenance message four times until the
meter automatically resets.
• 100 hours - CHG OIL — Oil Change Inter
-
val (Every 100 hrs)
• 200 hours - SVC — Service Air Filter
(Every 200 hrs)
NOTE:
The hour glass icon will flash when the
engine is running. This signifies the meter is
recording hours of operation.
Figure 2-6. Hour Meter
Connection Plugs
120 VAC, 20 Amp, Duplex
Receptacle (if equipped)
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See
. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater).
Figure 2-7. 120 VAC, 20 Amp, Duplex
Receptacle NEMA 5-20R
120 VAC, 20 Amp, GFCI Duplex
Receptacle (if equipped)
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See
. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater). It also pro
-
vides protection with a Ground Fault Circuit
Interrupter with a press to TEST and RESET
button.
Engine Specifications
PM3800
PM4500
PM4500E
Displacement
212 cc
224 cc
Spark Plug Part No.
0J00620106
Spark Plug Type
F7TC or equivalent
Spark Plug Gap
0.028-0.031 inch or (0.70-0.80 mm)
Gasoline Capacity
18.9 L (5 gal)
Oil Type
See Chart in
Oil Capacity
0.6 L (.63 qt.)
Run Time at 25% / 50% Load
21.5 / 14.5 Hours
19 / 14 Hours
* Go to
www.powermate.com
or contact an IASD for replacement parts.
Product Specifications
0000.0
000205
000424
Содержание PM3800
Страница 26: ...24 Owner s Manual for Portable Generator Wiring Diagrams PM3800 CSA 010937...
Страница 27: ...Owner s Manual for Portable Generator 25 PM4400E CSA 010938...
Страница 28: ...26 Owner s Manual for Portable Generator PM4500 CSA 010939...
Страница 29: ...Owner s Manual for Portable Generator 27 Notes...
Страница 30: ...28 Owner s Manual for Portable Generator...
Страница 31: ......
Страница 61: ...Manual del usuario del generador port til 27 Diagramas de cableado PM3800 CSA 010937...
Страница 62: ...28 Manual del usuario del generador port til PM4400E CSA 010938...
Страница 63: ...Manual del usuario del generador port til 29 PM4500 CSA 010939...
Страница 93: ...Manuel du propri taire du g n rateur portatif 27 Sch mas de c blage PM3800 CSA 010937...
Страница 94: ...28 Manuel du propri taire du g n rateur portatif PM4400E CSA 010938...
Страница 95: ...Manuel du propri taire du g n rateur portatif 29 PM4500 CSA 010939...