SAFETY INSTRUCTIONS FOR SLIDE GATE OPERATING SYSTEMS 

SAFETY IS EVERYONE'S BUSINESS

 

Important!! 

 
 
 
 
 
 
Automatic gate operators provide convenience and security to users. However, because these machines can 
produce high levels of force, it is important that all gate operator system designers, installers, and end users 
be aware of the potential hazards associated with improperly designed, installed, or maintained systems. 
Keep in mind that the gate operator is a component of a total gate operating system. 
 
The following information contains various safety precautions and warnings for the system designer, 
installer, and end user. These instructions provide an overview of the importance of safe design, 
installation, and use. 
 
Warnings are identified with the symbol 

. This symbol will identify some of the conditions that can result 

in serious injury or death. Take time to carefully read and follow these precautions and other important 
information provided to help ensure safe system design, installation, and use. 
 
WARNING: Gate operators are only one part of a 

total gate operating system

. It is the responsibility of 

the purchaser, designer, and installer to ensure that the total system is safe for its intended use. All 
secondary entrapment safety devices must be U/L recognized to complete the operating system. 

 
 

SYSTEM DESIGNER SAFETY INSTRUCTIONS

 

 
 

1. 

 Familiarize yourself with the precautions and warnings for the installer. Users are relying on your 

design to provide a safe installation. 

2. 

 The operator is supplied with a primary current sensing entrapment protection system. The 

installation must also have a secondary entrapment protection system installed, such as photoelectric 
sensors or an electric edge system (See page 8 & 9). 

3. 

 When designing a system that will be entered from a highway or main thoroughfare, make sure the 

system is placed far enough away from the road to eliminate traffic backup. Distance from the road, size 
of the gate, usage levels, and gate cycle/speed must be considered to eliminate potential traffic hazards. 

4. 

 The majority of injuries from slide gate operator systems occur with Open Rollers or Ornamental 

Grill Type Gates. The illustrations and descriptive captions found on the following pages provide 
precautions to help eliminate injuries or fatalities. Familiarize yourself with them when designing the 
total system. 

5. 

 Design gate systems so a person(s) cannot reach through the gate to operate any controls. Never 

place controls on the gate operator itself 

Содержание RSG 2000

Страница 1: ...herewith X Class II Commercial General Access Vehicular Gate Operator A vehicular gate operator or system intended for use in a commercial location or building such as a multifamily housing unit five...

Страница 2: ...er to ensure that the total system is safe for its intended use All secondary entrapment safety devices must be U L recognized to complete the operating system SYSTEM DESIGNER SAFETY INSTRUCTIONS 1 Fa...

Страница 3: ...the automatic controls do not work Locate the push button or key switch and small warning placard within sight of gate in a secured area at least 10 feet or more from the gate and fence to keep users...

Страница 4: ...e sure roller guards have been purchased and installed 7 Your gate system is required to have a primary and a secondary entrapment safety system installed and maintained See page 7 8 8 If your gate cl...

Страница 5: ...caught between the grille and the fence post or fence The potential hazard must be guarded It can be simply done by placing a screen mesh on the gate and fence in the area of the gate The screen must...

Страница 6: ...d cementing of mounting posts minimum of 2 deep 3 Set mounting posts and electrical conduits in place 4 Pour cement to secure mounting posts and let cure for two days prior to operator installation No...

Страница 7: ...ocket See Figs 3 6 8 Pull drive chain though to opposite end of gate cut to correct length and secure to gate bracket using 3 8 inch chain take up bolt as done in steps 4 and 5 Note When pulling drive...

Страница 8: ...ntacts must be NORMALLY OPEN Connect STOP button to terminal 4 Connect COMMON button to terminal 5 Connect OPEN button to terminal 6 Connect CLOSE to terminal 7 PRIMARY OBSTRUCTION SENSING DEVICE Note...

Страница 9: ...te Install photoelectric cell as close to inside of gate as possible Note Photo cells should be installed across gate opening and behind gate See Fig 11 at least 10 inches above ground 1 After sensors...

Страница 10: ...adio s installation manual to determine which wires are for the normally open contacts and which require the 24 VAC power supply TIMER TO CLOSE The operator is equipped with a timer to close option fo...

Страница 11: ...wrong turn off main power and recheck drive chain installation See Fig 4 6 If drive chain is correct consult the factory WARNING UNDER NO CIRCUMSTANCES SHOULD CONTROL STATION WIRING BE ALTERED IF ROTA...

Страница 12: ...ENTRY Open only 1 Connect MO to terminal 3 2 Connect common to terminal 5 DO NOT Connect N O to terminal 6 FIG 6 EXIT LOOP Open only 1 Connect common yellow to terminal 3 2 Connect N O blue to termina...

Страница 13: ...13...

Отзывы: