background image

11 

 

LIMIT ADJUSTMENT PROCEDURE:

 

 

WARNING:

 TURN OFF MAIN POWER BEFORE MAKING ANY ADJUSTMENTS! 

 
1.  After gate is mechanically installed and controls are connected, set gate in midway position, using the 

manual disconnect. 

2.  Depress pressure plate and set grooved limit nuts approximately I inch from limit switches on each side 

(See Fig. 14).  

 

WARNING: STAY CLEAR OF ALL MOVING PARTS AND ELECTRICAL COMPONENTS 

OF OPERATOR WHILE TESTING!

 

3.   

 Connect power. 

4.  Open gate electrically. If gate travels in correct direction and stops at open limit, proceed to step 7. If 

gate travels in the correct direction and nears the end of gate travel BUT DOES NOT STOP, STOP 
GATE with stop button or by removing power. Check too see if open limit has been tripped. If it has 
NOT been tripped:  
(a.) Turn off power.  
(b.) Manually move gate to midway position.  
(c.) Set open limit nut closer to open limit switch.  
(d.) Repeat procedure. If open limit switch has been tripped, but did not stop gate, consult the factory. 

5.  If direction of travel in wrong, turn off main power and recheck drive chain installation (See Fig. 4 & 

6). If drive chain is correct, consult the factory. 

 

 

WARNING: UNDER NO CIRCUMSTANCES 

SHOULD CONTROL STATION WIRING BE ALTERED 
IF ROTATION IS INCORRECT. TO DO SO WILL 
CAUSE SOME CONTROL FUNCTIONS TO BE 
INOPERATIVE, WHICH MAY RESULT IN PERSONAL 
INJURY OR DAMAGE TO GATE AND/OR OPERATOR.

 

 
6.  If operator functions properly, disconnect power, and proceed to limit adjustment. 
7.  Limit adjustment: Depress pressure plate and rotate grooved limit nut, on limit shaft, closest to open 

limit switch (See Fig. 14). To stop gate earlier, move limit nut closer to open limit switch. To stop gate 
later, back limit nut away from limit switch. 

Note:

 When making fine adjustments, turn limit nut 1/4 to 

1/2 turn at a time, reconnect power and test run gate. 

8.  Repeat procedure for close limit adjustment. 
9.  After the desired open and closed position of gate has been obtained, make certain that a groove in both 

limit nuts is engaged by the pressure plate. 

 

SERVICE:

 

 
Lubricate drive chain and idler sprocket bearings monthly with 30 WGT. oil. Periodically check all 
hardware (nuts, bolts, screws, etc..) for tightness. 
 
 
 

PowerMaster Technical Service Line: 

1-800-243-4476

 

 

Содержание RSG 2000

Страница 1: ...herewith X Class II Commercial General Access Vehicular Gate Operator A vehicular gate operator or system intended for use in a commercial location or building such as a multifamily housing unit five...

Страница 2: ...er to ensure that the total system is safe for its intended use All secondary entrapment safety devices must be U L recognized to complete the operating system SYSTEM DESIGNER SAFETY INSTRUCTIONS 1 Fa...

Страница 3: ...the automatic controls do not work Locate the push button or key switch and small warning placard within sight of gate in a secured area at least 10 feet or more from the gate and fence to keep users...

Страница 4: ...e sure roller guards have been purchased and installed 7 Your gate system is required to have a primary and a secondary entrapment safety system installed and maintained See page 7 8 8 If your gate cl...

Страница 5: ...caught between the grille and the fence post or fence The potential hazard must be guarded It can be simply done by placing a screen mesh on the gate and fence in the area of the gate The screen must...

Страница 6: ...d cementing of mounting posts minimum of 2 deep 3 Set mounting posts and electrical conduits in place 4 Pour cement to secure mounting posts and let cure for two days prior to operator installation No...

Страница 7: ...ocket See Figs 3 6 8 Pull drive chain though to opposite end of gate cut to correct length and secure to gate bracket using 3 8 inch chain take up bolt as done in steps 4 and 5 Note When pulling drive...

Страница 8: ...ntacts must be NORMALLY OPEN Connect STOP button to terminal 4 Connect COMMON button to terminal 5 Connect OPEN button to terminal 6 Connect CLOSE to terminal 7 PRIMARY OBSTRUCTION SENSING DEVICE Note...

Страница 9: ...te Install photoelectric cell as close to inside of gate as possible Note Photo cells should be installed across gate opening and behind gate See Fig 11 at least 10 inches above ground 1 After sensors...

Страница 10: ...adio s installation manual to determine which wires are for the normally open contacts and which require the 24 VAC power supply TIMER TO CLOSE The operator is equipped with a timer to close option fo...

Страница 11: ...wrong turn off main power and recheck drive chain installation See Fig 4 6 If drive chain is correct consult the factory WARNING UNDER NO CIRCUMSTANCES SHOULD CONTROL STATION WIRING BE ALTERED IF ROTA...

Страница 12: ...ENTRY Open only 1 Connect MO to terminal 3 2 Connect common to terminal 5 DO NOT Connect N O to terminal 6 FIG 6 EXIT LOOP Open only 1 Connect common yellow to terminal 3 2 Connect N O blue to termina...

Страница 13: ...13...

Отзывы: