20
Every 8 hours or daily
Check oil level
Clean around air intake and muffler
First 5 Hours
Change oil
First 10 hours
Check/Adjust Valve Clearance *
Every 50 hours or every season
Clean air filter
Change oil if operating under heavy load or in hot environments
Every 100 hours or every season
Change oil
Clean/Adjust spark plug
Check/Adjust valve clearance *
Clean spark arrester
Every 3 years
Replace LPG /NG tube
* To be performed by knowledgeable, experienced owners or certified service dealer
Generator Maintenance
Make certain that the generator is kept clean and stored properly. Only operate the unit on a
flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme
conditions, excessive dust, dirty, moisture or corrosive vapors.
CAUTION
: DO NOT use a garden hose to clean the generator.
●
Water can enter the generator through the cooling slots and damage the generator
windings.
Use a damp cloth to clean exterior surfaces of the generator.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris from the generator.
Inspect all air vents and cooling slots to ensure that they are clean and unobstructed.