![PowerLand PDL4000 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/powerland/pdl4000/pdl4000_manual_1589588009.webp)
5
CONTROLS AND FEATURES
Read this owner’s manual before operating your generator. Familiarize yourself with the
location and function of the controls and features. Save this manual for future reference.
Air cleaner-
a removable, cleanable, sponge-like el ement that limit s the amount of dirt
pulled into the engine.
Gas inlet-
with High-pressure intake tube connect to
LPG tank or NG connecting tube
.
Reducer assy. –
Adjust LPG or NG inlet gas high-pr essure to st able pres sure, then
supply for mix device.
Circuit Breaker-
Reset switch that protects the generator from electrical overload.
AC Receptacle-
Use to connect electrical devices that run, single phase, AC current.
Ground Terminal-
Connect grounding wires here to properly ground unit.
Volt Meter-
Provides reading of voltage output.
Oil Filler Cap-
Use to Add oil or checking the oil.
Engine Oil Drain Plug-
Drain the oil or change oil.
Engine Switch-
Used to start/stop engine.
Recoil Starter-
Pull-cord for starting engine.
Voltage selector switch-
The main power carrying windings of the generator to produce
"120V ONLY" or "120/240V".