Grounding
Your generator must be properly connected to an appropriate ground to help prevent
electric shock.
The generator system ground connects the frame to the ground terminals on
the power panel. The system ground is connected to the AC neutral wire.
WARNING
: Failure to properly ground the generator
can result in electric shock. A
ground terminal connected to the frame of the generator has been provide d
on the power panel. For remote grounding, connect of a length of heavy
gauge (14 AWG minimum) copper wire
between the generator ground
terminal and a copper rod driven into the ground. We strongly recommend
that you consult with a qual ified electrician to ens ure compliance with local
electrical codes.
Generator Location
Please consult your local authority. In some areas, generators must be registered with the
local utility.
Generators used at construction sites may be subject to additional rules and regulations.
This generator must have at least five feet of clearance from combustible material. Leave at
least three feet of clearance on all sides of the generator to allow for adequate cooling,
maintenance and servicing.
Place the generator in a well-ventilated area.
DO NOT place the generator near vents or intakes where exhaust fumes could be drawn
into occupied or confined spaces. Carefully consider wind and air currents when positioning
generator.
WARNING:
1. When using the LPG/NG generator, please be sure that there are some
distance between LGP tank or NG connecting tube and the generator, to
prevent unnecessary danger because of high temperature surface of LGP
tank.
2. When using the unit, please check the surface temperature of LPG tank.
3. Don't place the LPG tank in one place where ambient temperature above
35 and use LPG
℃
/NG for electricity generating.