6
WARNING: DO NOT
exceed the generator’s wattage/amperage capacity. Our products are
continuously being changed and improved. Every effort has been made to ensure that
information in the manual is accurate and up to date. However, we reserve the right to
change, alter or otherwise improve the product and this manual at any time without prior
notice.
Instruction of gas denser device
To develop cold start performance of LPG/NG generator unit, the mix devic e( the same as
carburetor) includes a gas denser device, the detailed operation is as below.
When start the cold LPG/NG generator unit, open t he valve of LPG tank or NG connecting
tube, Start the engine normally. If cannot start, pull the gas denser device lever lightly, and
keep 1-2 seconds, then stop, and then restart the engine.
CAUTION
: Improper treatment or use of the generator can damage it, shorten its life and
void your warranty
.
●
The lever only does work after turning on the gas source valve, if start normally, no
need pull the lever, or it will cause generator unit work abnormally;
●
When pull the lever, the keeping time must not over 2 seconds, otherwise it is not
good for start; No need to pull the lever at every start, only need to use when the first
start of the cold generator unit or when need to change Gas;
●
If with abnormality, please contact us;
●
Prohibit adjusting the LPG/NG gas-pressure adjusting screw and gas flow adjusting
screw.
Add Engine Oil
CAUTION
: DO NOT attempt to crank or start the engine before it has been properly filled
with the recommended type and amount of oil. Damage to the generator as a
result of failure to follow these instructions will void your warranty.