29
TROUBLESHOOTING
Problem
Cause
Solution
Engine switch is set to “off”.
Set engine switch to “on”.
Fuel valve is turned to “closed”.
Turn fuel valve to “open” position.
Choke is open.
Close the choke
Engine is out of gas.
Add gas.
Engine
is
filled
with
contaminated or old gas
Change the gas on the engine.
Spark plug is dirty.
Clean spark plug.
Spark plug is broken.
Replace spark plug.
Generator is not on level
surface.
Move generator to a level surface to
prevent low oil shutdown from
triggering.
Engine will not
start
Oil is low
Add or replace oil.
Circuit breaker is off.
Set the circuit breaker to the “on”
position.
Bad connecting wires/cables.
If you are using an extension cord,
try a different one.
Engine runs but
there
is
no
electrical output
Bad
electrical
device
connected to generator.
Try connecting a different device.
Generator is overloaded
Try connecting fewer electrical loads
to the generator.
Out of gas
Fill gas tank
Short in one of the connected
devices.
Try disconnecting any faulty or
short-circuited electrical loads.
Generator
runs
but
does
not
support
all
electrical devices
connected.
Air cleaner is dirty.
Clean or replace air cleaner.
Change the Carbon-Brush
Содержание PD3G10000E
Страница 34: ...30 Change the AVR...
Страница 38: ...34 WIRING DIAGRAM PD3G4400E...
Страница 39: ...35 PD3G6500E...
Страница 40: ...36 PD3G8500E...
Страница 41: ...37 PD3G10000E...
Страница 42: ...38 EXPLODED VIEW AND PARTS LIST...
Страница 45: ...41...