background image

42

Item Part

Qty Description

Item Part

Qty Description

1

1

Gasoline engine

41

14300

1

Fuel filler cap comp

2

15100

1

Frame comp

42

14400

1

Fuel sensor

3

15002

2

Bottom rubber A

43

GB 819-95

2

Screw M5

×

10

4

15003

2

Bottom rubber B

44

14410

1

Casket fuel tank

5

GB6177-86

16

Flange nut M8

45

GB5787-86

4

Flange bolt M6

×

22

6

32000

1

Reducer assy.

46

14022

4

Washer 

7

32004

1

Intake hose

47

14005

4

Collar 

8

GB5787-86

24

Bolt M6

×

12

48

14001

4

Cushion

9

15001

2

Rubber pad, frame

49

14004

1

Outlet pipe

φ

4.5

×

165

10

15201

2

Hand push

50

14006

2

Tube clip

11

11010

1

Earth terminal set

51

14003

1

Rubber, fuel tube

12

GB5787-86

8

Flange bolt M6

×

12

52

14100

1

Fuel cock

13

11070

1

Receptacles (30A)

53

32001

2

Clip

14

11073

1

Receptacles (50A)

55

GB5787-86

2

Flange bolt M8

×

32

15

11072

1

Receptacles (20A)

56

13010

1

Muffler stay

16

11120

2

Circuit Breaker

57

13020

1

Muffler 

17

11090

1

Control panel

59

GB5789-86

10

Flange bolt M8

×

16

18

11110

1

LED smart meter

64

11101

2

DC output post

19

11050

2

Diode assay

65

11105

1

Voltage selection switch

20

11082

1

Engine switch

66

GB6177-86

2

Flange nut M12

21

11040

1

Boot, switch wire 

67

GB97.1-85

2

Washer 

φ

20

22

11030

1

Boot, main wire harness

68

21040

2

Wheel comp 

23

11010

1

Boot, AC output wire

69

21020

2

Bracket 

24

11060

1

Wire harness Assy.

70

21010

1

Axle

25

GB5787-86

5

Flange bolt M5

×

12

179

11096

1

Fuse(5A)

26

16004

1

Generator end cover

180

22001

1

Positive wire of battery

27

GB5789-86

4

Flange bolt M6

×

200

181

22002

1

Negative wire of battery

28

16003

1

Support stand

182

22005

1

Battery cover

29

GB5789-86

1

Bolt M10

×

1.25

×

290

183

22010

1

Battery 

30

GB9701-85

1

Plain washer

φ

10

184

11070

1

Brush assy.

31

GB276-89

1

Bearing 6207-2RS

185

11080

1

Voltage regulator

32

16200

1

Rotor comp

186

15010

1

Protector frame side

33

16000

1

Stator & Rotor Assy.

187 15011

2

Frame cover

34

16005

1

Generator fan

188

15102

1

Frame comp

side

35

16101

1

Stator cover

189

21000

1

Wheel Assembly

36

16100

1

Stator Assy.

190

15012

1

Protector panel side

37

14201

1

Stripe, fuel tank

191

15013

1

Protector Battery side

38

14200

1

Fuel tank

192

11193

1

AC protector

39

14302

1

Fuel filter

193

11195

1

DC protector (10A)

40

14303

1

Packing ring

194

11071

1

Receptacles (30A)

Содержание PD3G10000E

Страница 1: ...the operation and maintenance of these products We have made every effort to ensure the accuracy of the information in this manual We reserve the right to change this product at any time without prior...

Страница 2: ...ine Speed 3600 rpm Compression Ratio 8 5 1 8 0 1 Displacement 208 cc 419 cc Starting type Electric start Recoil Use clean fresh regular LPG with LPG gas pressure area 10 15 PSI Use clean fresh regular...

Страница 3: ...ORDS ABOUT SAFETY Your safety and the safety of others is very important And using this generator safely is an important responsibility To help you make informed decisions about safety we have provide...

Страница 4: ...stem 9 AC Applications 9 AC Operation 9 AC Receptacle Selection 10 DC Operation 11 PRE OPERATION CHECK 12 Engine Oil 12 Fuel Recommendation 13 STARTING THE ENGINE STOPPING THE ENGINE 17 MAINTENANCE 19...

Страница 5: ...ause loss of consciousness and may lead to death If you run the generator in an area that is confined or even partially enclosed the air you breathe could contain a dangerous amount of exhaust gas To...

Страница 6: ...engine stopped Fuel vapors are extremely flammable and may ignite after the engine has started Make sure that any spilled fuel has been wiped up before starting the generator Always keep fuel away fro...

Страница 7: ...3 COMPONENT IDENTIFICATION Record the engine and frame serial numbers for your future reference Refer to these serial numbers when ordering parts and when making technical or warranty inquiries...

Страница 8: ...the starter grip to snap back against the engine Return it gently to prevent damage to the starter The recoil starter is used to start the engine if the generator is not equipped with a 12 volt batter...

Страница 9: ...ong receptacle the switch must be in the 120 240V position If only a 120V appliance is being connected to any of the 120V 3 prong receptacles select the 120V ONLY position 120 240V The 120V and 120 24...

Страница 10: ...E TERMINAL RED DC CIRCUIT PROTECTOR OFF ON OFF ON DC CIRCUIT PROTECTOR NEGATIVE TERMINAL BLACK POSITIVE TERMINAL RED DC Circuit Protector The DC circuit protector automatically shuts off the DC batter...

Страница 11: ...is recommended that the auto throttle be kept in the ON position if less than 50 load is being used If the generator will be running over 50 it is recommended that you switch to the OFF position OFF O...

Страница 12: ...o put the NG hose to the NG inlet make the LPG inlet screw and seal well with the nut and turn the LPG NG selector switch to the NG position When start the cold LPG NG generator unit open the valve of...

Страница 13: ...rator Make sure that it is in good working order Faulty appliances or power cords can become hazardous and cause electrocution If an appliance begins to operate abnormally operates sluggish or stops s...

Страница 14: ...e 120 240V position When two or more receptacles are used to prevent overloading dividing the load between the two power circuits Example The chart below shows the rated load in amperes that can be co...

Страница 15: ...art the vehicle while the battery charging cable is connected and the generator is running The vehicle or the generator may be damaged An overloaded DC circuit excessive current draw by the battery or...

Страница 16: ...affecting engine performance and service life Non detergent and 2 stroke engine oils will damage the engine and are not recommended Check the oil level BEFORE EACH USE with the generator on a level su...

Страница 17: ...ngine and keep heat sparks and flame away Only refuel outdoors Wipe up spills immediately It is important to use new clean fuel when refueling your unit for optimal performance FUEL FILLER CAP FUEL GA...

Страница 18: ...ed and meets the minimum octane rating requirement Before using an oxygenated fuel try to confirm the fuel s contents Some states provinces require this information to be posted on the pump The follow...

Страница 19: ...there are no leaks CAUTION Use clean fresh regular LPG with LPG gas pressure area as we required DO NOT mix oil with fuel DO NOT use CNG or NG Clean the area around the fuel cap Connect LPG hose on L...

Страница 20: ...nd then verify that there are no leaks CAUTION Use clean fresh regular NG with NG gas pressure area as we required DO NOT mix oil with fuel DO NOT use LPG CNG or gasoline as fuel Clean the area around...

Страница 21: ...e generator rear housing Turn the engine switch to the START position and hold it there for 5 seconds or until the engine starts When the engine starts allow the engine switch to return to the ON posi...

Страница 22: ...c start or pull cord and unit does not start the unit is flooded Shut off all fuel sources and turn key to start activating the electric start for 3 5 seconds Then restart normally NOTICE Please don t...

Страница 23: ...ouble free operation It will also help reduce air pollution WARNING Improper maintenance or failure to correct a problem can cause a malfunction in which you can be seriously injured or killed Always...

Страница 24: ...ructed to do so Read the instructions before you begin and make sure you have the tools and skills required To reduce the possibility of fire or explosion be careful when working around gasoline Use o...

Страница 25: ...Afterburning backfiring Black exhaust smoke or high fuel consumption Replacement Parts The emission control systems on your engine were designed built and certified to conform to EPA and California em...

Страница 26: ...oderate 50 hours 0 65 cc 125 hours greater than 65 cc Intermediate 125 hours 0 65 cc 250 hours greater than 65 cc Extended 300 hours 0 65 cc 500 hours greater than 65 cc The Air Index Information hang...

Страница 27: ...OIL DRAIN PLUG Wash your hands with soap and water after handling used oil Please dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed cont...

Страница 28: ...d filter 2 Clean the sediment cup O ring and filter in nonflammable or high flashpoint solvent 3 Reinstall the filter O ring and sediment cup 4 Turn the fuel valve lever ON and check for leaks Spark P...

Страница 29: ...s seated tighten with a spark plug wrench to compress the washer If installing a new spark plug tighten 1 2 turn after the spark plug seats to compress the washer If reinstalling a used spark plug tig...

Страница 30: ...izer 2 months to 1 year Fill with fresh gasoline and add gasoline stabilizer Drain the carburetor float bowl Drain the fuel sediment cup 1 year or more Fill with fresh gasoline and add gasoline stabil...

Страница 31: ...ute the oil then reinstall the spark plug 4 Slowly pull the starter grip until resistance is felt At this point the piston is coming up on its compression stroke and both the intake and exhaust valves...

Страница 32: ...cially careful of the following Read the instructions before you begin and be sure you have the tools and skills required to perform the tasks safely Make sure the engine is off before you begin any m...

Страница 33: ...ng Engine will not start Oil is low Add or replace oil Circuit breaker is off Set the circuit breaker to the on position Bad connecting wires cables If you are using an extension cord try a different...

Страница 34: ...30 Change the AVR...

Страница 35: ...uit interrupters GFCIs as per the manufacturer s instructions Do not connect a generator to a structure unless the generator has a properly installed transfer switch Visually inspect the equipment bef...

Страница 36: ...Work Practices for Portable Tools include Do not use underrated cords replace them with appropriately rated cords that use heavier gauge wires Never use electrical tools or appliances with frayed cor...

Страница 37: ...nection How to ground Powerland generator 1 Tools you will need Sledgehammer cooper wire Show in picture 1 picture 1 2 Wire the cooper line onto the knob on the panel as shown in picture 2 3 Wire the...

Страница 38: ...34 WIRING DIAGRAM PD3G4400E...

Страница 39: ...35 PD3G6500E...

Страница 40: ...36 PD3G8500E...

Страница 41: ...37 PD3G10000E...

Страница 42: ...38 EXPLODED VIEW AND PARTS LIST...

Страница 43: ...6 1 Seat valve spring 91 GB5789 86 2 Flange bolt M6 25 143 11212 1 Retainer EX Valve spring 92 21010 1 Contactor Assy 144 11213 1 Rotator valve 97 81102 1 Cord stop switch 145 11211 1 Retainer IN Valv...

Страница 44: ...Rod governor 169 13105 2 Clip piston pin 178 17005 1 Bolt governor arm 170 13101 1 Piston 195 GB5787 86 1 Flange bolt M6 30 171 13104 1 Pin piston 196 GB5787 86 1 Flange bolt M3 8 172 13106 1 Connecti...

Страница 45: ...41...

Страница 46: ...ay 65 11105 1 Voltage selection switch 20 11082 1 Engine switch 66 GB6177 86 2 Flange nut M12 21 11040 1 Boot switch wire 67 GB97 1 85 2 Washer 20 22 11030 1 Boot main wire harness 68 21040 2 Wheel co...

Страница 47: ...ill not operate normally if the altitude is above 3000 feet If you find that you are not able to run the unit after receiving it due to altitude above 3000 feet and you did not check your altitude bef...

Отзывы: