39

Item

Part

Qty

Description

Item

Part

Qty

Description

71

21100

1

Starter comp, recoil

121

12006

1

Stay, air cleaner

72

GB5787-86

3

Flange bolt M6×8

122

12005

1

Case comp, air cleaner

73

12310

1

Fan, cover comp

123

12004

1

Separator, air cleaner

74

GB5787-86

13

Flange bolt M6×12

124

GB6177-86

6

Flange nut M5

75

19003

1

Shroud comp

125

12007

1

Cover comp, air cleaner

76

12302

3

Clip. Wire darkness 

126

12008

2

Clip, air cleaner ware 

77

12302

1

Grommet drain hole

127

12003

1

Element, air cleaner

78

21000

1

Start motor

128

12010

1

Seal, air cleaner 

79

GB5789-86

2

Flange bolt M8×35

129

23003

1

Packing, insulator

80

GB6177-86

1

Flange nut M16

132

91009

1

Tube, fuel φ45×165

81

19005

1

Pulley, starter

133

12001

1

Tube, breather

82

19001

1

Fan, cooling

134

GB5789-86

4

Flange bolt M10×80

83

GB/T 99-88

1

Key 

135

11250

1

Head comp, cylinder

84

81200

1

Flywheel comp

136

11217

2

Bolt head, M8×34

85

12215

2

Oil seal, 35×52×8

137

11202

1

Plug, spark

86

12200

1

Crank case assy.

138

15100

1

Camshaft assy.

87

87500

1

Amplifier 

139

15002

2

Lifter, valve

88

12203

2

Bolt, drain lug

140

11208

1

Valve, IN.

89

12217

2

Washer, drain lug

141

11209

1

Valve, EX.

90

87601

1

Clip, wire

142

11216

1

Seat, valve spring

91

GB5789-86

2

Flange bolt M6×25

143

11212

1

Retainer, EX. Valve spring

92

21010

1

Contactor Assy.

144

11213

1

Rotator, valve

97

81102

1

Cord stop switch

145

11211

1

Retainer, IN. Valve spring

98

81103

1

Grommet cord 

146

11206

2

Spring, valve

99

81100

1

Coil assy. ignition

147

15001

2

Rod, push

100

12216

1

Oil seal, 8×14×5

148

11241

1

Exhaust piper

101

GB/T276-94

2

Bearing (6202)

149

11240

1

Cover comp, head

102

12208

1

Shaft, governor arm

150

11243

1

Washer comp head cover

103

12212

1

Pin, lock, 10mm

151

11242

1

Bolt, head cover

104

12209

1

Washer, 8.2×17×0.8

152

GB6175-86

2

Nut M8

105

GB6177-86

1

Flange nut M10

153

13200

1

Pipe comp EX.

106

12221

1

O-ring,14mm

154

13202

1

Casket (B) EX. Pipe

107

12200

1

Switch assy. oil level

155

11215

1

Plate, push rod guide

108

13200

1

Weight, balancer

156

11214

2

Bolt, pivot

109

13000

1

Crankshaft comp

157

11205

2

Arm, valve rocker

110

GB/T276-94

2

Bearing (6207)

158

11204

2

Nut, Arm, valve rocker

111

12220

2

Pin, dowel, 12×20

159

11206

2

Nut, pivot adjusting

112

11219

1

Casket, cylinder head

160

GB5789-86

7

Flange bolt M8×40

113

11218

2

Bolt head, 8×106

161

12100

1

Crankcase cover

114

23008

2

Packing, air cleaner

162

GB5789-86

3

Flange bolt M5×10

117

23000

1

Mixer   

163

12301

1

Fan cover

118

23002

1

Packing, carburetor

164

121102

1

Cap assy. oil filler

119

23001

1

Insulator, carburetor

165

12230

1

Governor kit

Содержание PD3G10000E

Страница 1: ...the operation and maintenance of these products We have made every effort to ensure the accuracy of the information in this manual We reserve the right to change this product at any time without prior...

Страница 2: ...ine Speed 3600 rpm Compression Ratio 8 5 1 8 0 1 Displacement 208 cc 419 cc Starting type Electric start Recoil Use clean fresh regular LPG with LPG gas pressure area 10 15 PSI Use clean fresh regular...

Страница 3: ...ORDS ABOUT SAFETY Your safety and the safety of others is very important And using this generator safely is an important responsibility To help you make informed decisions about safety we have provide...

Страница 4: ...stem 9 AC Applications 9 AC Operation 9 AC Receptacle Selection 10 DC Operation 11 PRE OPERATION CHECK 12 Engine Oil 12 Fuel Recommendation 13 STARTING THE ENGINE STOPPING THE ENGINE 17 MAINTENANCE 19...

Страница 5: ...ause loss of consciousness and may lead to death If you run the generator in an area that is confined or even partially enclosed the air you breathe could contain a dangerous amount of exhaust gas To...

Страница 6: ...engine stopped Fuel vapors are extremely flammable and may ignite after the engine has started Make sure that any spilled fuel has been wiped up before starting the generator Always keep fuel away fro...

Страница 7: ...3 COMPONENT IDENTIFICATION Record the engine and frame serial numbers for your future reference Refer to these serial numbers when ordering parts and when making technical or warranty inquiries...

Страница 8: ...the starter grip to snap back against the engine Return it gently to prevent damage to the starter The recoil starter is used to start the engine if the generator is not equipped with a 12 volt batter...

Страница 9: ...ong receptacle the switch must be in the 120 240V position If only a 120V appliance is being connected to any of the 120V 3 prong receptacles select the 120V ONLY position 120 240V The 120V and 120 24...

Страница 10: ...E TERMINAL RED DC CIRCUIT PROTECTOR OFF ON OFF ON DC CIRCUIT PROTECTOR NEGATIVE TERMINAL BLACK POSITIVE TERMINAL RED DC Circuit Protector The DC circuit protector automatically shuts off the DC batter...

Страница 11: ...is recommended that the auto throttle be kept in the ON position if less than 50 load is being used If the generator will be running over 50 it is recommended that you switch to the OFF position OFF O...

Страница 12: ...o put the NG hose to the NG inlet make the LPG inlet screw and seal well with the nut and turn the LPG NG selector switch to the NG position When start the cold LPG NG generator unit open the valve of...

Страница 13: ...rator Make sure that it is in good working order Faulty appliances or power cords can become hazardous and cause electrocution If an appliance begins to operate abnormally operates sluggish or stops s...

Страница 14: ...e 120 240V position When two or more receptacles are used to prevent overloading dividing the load between the two power circuits Example The chart below shows the rated load in amperes that can be co...

Страница 15: ...art the vehicle while the battery charging cable is connected and the generator is running The vehicle or the generator may be damaged An overloaded DC circuit excessive current draw by the battery or...

Страница 16: ...affecting engine performance and service life Non detergent and 2 stroke engine oils will damage the engine and are not recommended Check the oil level BEFORE EACH USE with the generator on a level su...

Страница 17: ...ngine and keep heat sparks and flame away Only refuel outdoors Wipe up spills immediately It is important to use new clean fuel when refueling your unit for optimal performance FUEL FILLER CAP FUEL GA...

Страница 18: ...ed and meets the minimum octane rating requirement Before using an oxygenated fuel try to confirm the fuel s contents Some states provinces require this information to be posted on the pump The follow...

Страница 19: ...there are no leaks CAUTION Use clean fresh regular LPG with LPG gas pressure area as we required DO NOT mix oil with fuel DO NOT use CNG or NG Clean the area around the fuel cap Connect LPG hose on L...

Страница 20: ...nd then verify that there are no leaks CAUTION Use clean fresh regular NG with NG gas pressure area as we required DO NOT mix oil with fuel DO NOT use LPG CNG or gasoline as fuel Clean the area around...

Страница 21: ...e generator rear housing Turn the engine switch to the START position and hold it there for 5 seconds or until the engine starts When the engine starts allow the engine switch to return to the ON posi...

Страница 22: ...c start or pull cord and unit does not start the unit is flooded Shut off all fuel sources and turn key to start activating the electric start for 3 5 seconds Then restart normally NOTICE Please don t...

Страница 23: ...ouble free operation It will also help reduce air pollution WARNING Improper maintenance or failure to correct a problem can cause a malfunction in which you can be seriously injured or killed Always...

Страница 24: ...ructed to do so Read the instructions before you begin and make sure you have the tools and skills required To reduce the possibility of fire or explosion be careful when working around gasoline Use o...

Страница 25: ...Afterburning backfiring Black exhaust smoke or high fuel consumption Replacement Parts The emission control systems on your engine were designed built and certified to conform to EPA and California em...

Страница 26: ...oderate 50 hours 0 65 cc 125 hours greater than 65 cc Intermediate 125 hours 0 65 cc 250 hours greater than 65 cc Extended 300 hours 0 65 cc 500 hours greater than 65 cc The Air Index Information hang...

Страница 27: ...OIL DRAIN PLUG Wash your hands with soap and water after handling used oil Please dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed cont...

Страница 28: ...d filter 2 Clean the sediment cup O ring and filter in nonflammable or high flashpoint solvent 3 Reinstall the filter O ring and sediment cup 4 Turn the fuel valve lever ON and check for leaks Spark P...

Страница 29: ...s seated tighten with a spark plug wrench to compress the washer If installing a new spark plug tighten 1 2 turn after the spark plug seats to compress the washer If reinstalling a used spark plug tig...

Страница 30: ...izer 2 months to 1 year Fill with fresh gasoline and add gasoline stabilizer Drain the carburetor float bowl Drain the fuel sediment cup 1 year or more Fill with fresh gasoline and add gasoline stabil...

Страница 31: ...ute the oil then reinstall the spark plug 4 Slowly pull the starter grip until resistance is felt At this point the piston is coming up on its compression stroke and both the intake and exhaust valves...

Страница 32: ...cially careful of the following Read the instructions before you begin and be sure you have the tools and skills required to perform the tasks safely Make sure the engine is off before you begin any m...

Страница 33: ...ng Engine will not start Oil is low Add or replace oil Circuit breaker is off Set the circuit breaker to the on position Bad connecting wires cables If you are using an extension cord try a different...

Страница 34: ...30 Change the AVR...

Страница 35: ...uit interrupters GFCIs as per the manufacturer s instructions Do not connect a generator to a structure unless the generator has a properly installed transfer switch Visually inspect the equipment bef...

Страница 36: ...Work Practices for Portable Tools include Do not use underrated cords replace them with appropriately rated cords that use heavier gauge wires Never use electrical tools or appliances with frayed cor...

Страница 37: ...nection How to ground Powerland generator 1 Tools you will need Sledgehammer cooper wire Show in picture 1 picture 1 2 Wire the cooper line onto the knob on the panel as shown in picture 2 3 Wire the...

Страница 38: ...34 WIRING DIAGRAM PD3G4400E...

Страница 39: ...35 PD3G6500E...

Страница 40: ...36 PD3G8500E...

Страница 41: ...37 PD3G10000E...

Страница 42: ...38 EXPLODED VIEW AND PARTS LIST...

Страница 43: ...6 1 Seat valve spring 91 GB5789 86 2 Flange bolt M6 25 143 11212 1 Retainer EX Valve spring 92 21010 1 Contactor Assy 144 11213 1 Rotator valve 97 81102 1 Cord stop switch 145 11211 1 Retainer IN Valv...

Страница 44: ...Rod governor 169 13105 2 Clip piston pin 178 17005 1 Bolt governor arm 170 13101 1 Piston 195 GB5787 86 1 Flange bolt M6 30 171 13104 1 Pin piston 196 GB5787 86 1 Flange bolt M3 8 172 13106 1 Connecti...

Страница 45: ...41...

Страница 46: ...ay 65 11105 1 Voltage selection switch 20 11082 1 Engine switch 66 GB6177 86 2 Flange nut M12 21 11040 1 Boot switch wire 67 GB97 1 85 2 Washer 20 22 11030 1 Boot main wire harness 68 21040 2 Wheel co...

Страница 47: ...ill not operate normally if the altitude is above 3000 feet If you find that you are not able to run the unit after receiving it due to altitude above 3000 feet and you did not check your altitude bef...

Отзывы: