60
Operation
2.2.5.1
Rotary brush remains
stopped because the ther-
mostatic switch has been
tripped.
The motor has overheated. For-
eign bodies (e.g. tape or such)
possibly block the rotary brush.
• Check the rotary brush for foreign bod-
ies and remove them, as necessary.
• Allow the motor to cool down.
• If the problem reoccurs, determine the
cause of overheating; contact anautho-
rized PowerBoss service center, if nec-
essary.
2.2.6.1
Rotary brush remains
stopped because the anti-
blocking system has been
tripped.
Foreign bodies (e.g. tape or
such) block the rotary brush.
Check the rotary brush for foreign bodies
and remove them, as necessary.
2.2.6.2
Rotary brush holding attach-
ment has been switched off
because the anti-blocking
system has been tripped.
Foreign bodies (e.g. tape or
such) between the rotary brush
and machine.
Check the rotary brush holding attachment
for foreign bodies, remove them as neces-
sary.
2.3.6.1
The left side brush (viewed
to the front of the vehicle)
stops because the anti-
blocking system has been
tripped.
Foreign bodies (e.g. tape or
such) block the side brush.
Check the side brushes for foreign bodies
and remove them, as necessary.